SD500 Spindle Servo Drive Manual
25
F01.02
(0x0102)
Frequency giving
source channel A
V/F SVC FVC PMVF PMSVC PMFVC
source channel A selection to give frequency for spindle
drive
0: Keyboard number entering
1: Keyboard analog potentiometer
2: Voltage analog AI1
3: Current/voltage analog AI2
4: Reserved
5: Terminal pulse PUL
6:RS485 communication
7: Terminal UP/DW control
8: PID control
9: Program control (PLC)
10: Positioning pulse terminal
11: Multi-speed
10
(0~11)
RUN
F01.03
(0x0103)
Frequency giving
source channel A gain
V/F SVC FVC PMVF PMSVC PMFVC
Gain of the frequency giving source channel A
100.0
(0.0~500.0%)
STOP
F01.04
(0x0104)
Frequency giving
source channel B
V/F SVC FVC PMVF PMSVC PMFVC
Source channel B selection to give frequency for spindle
drive, the same as [F01.02]
2
(0~11)
RUN
F01.05
(0x0105)
Frequency giving
source channel B gain
V/F SVC FVC PMVF PMSVC PMFVC
Gain of the frequency giving source channel B
100.0
(0.0~500.0%)
STOP
F01.06
(0x0106)
Reference frequency of
source channel B
V/F SVC FVC PMVF PMSVC PMFVC
The reference source for the frequency giving channel B is
selected by this parameter.
0: Maximum output frequency as the reference source
1: Channel A frequency set as the reference source
0
(0~1)
RUN
F01.07
(0x0107)
STOP
Selection of frequency
giving source
V/F SVC FVC PMVF PMSVC PMFVC
Used to select the combination of channel A and channel B
to set frequency for spindle drive.
0: Channel A
1: Channel B
2: Channel A+ Channel B
0
(0~5)
RUN