SD500 Spindle Servo Drive Manual
77
Group C04: Spindle feedback monitoring
Code (address)
Designation
Code (address)
Designation
C04.00 (0x2500)
Spindle position (pulse)
C04.25 (0x2519)
Spindle encoder pulse counting
C04.01 (0x2501)
Spindle position (angle)
C04.26 (0x251A)
Spindle encoder one-turn position
C04.02 (0x2502)
Spindle zero counting
C04.27 (0x251B)
Spindle encoder Z pulse detection
No.
C04.03 (0x2503)
Spindle external zero counting
C04.28 (0x251C)
Spindle encoder Z pulse cumulative
error
C04.04 (0x2504)
Spindle external zero position
C04.29 (0x251D)
Spindle encoder frequency (PU)
C04.15
Position error
Table 4-49
Group C05: Position control monitoring
Code (address)
Designation
Code (address)
Designation
C05.20 (0x2614)
Pulse command counting
C05.25 (0x2619)
Motor encoder pulse counting
C05.21 (0x2615)
Pulse counting increment
C05.26 (0x261A)
Motor encoder one-turn position
C05.22 (0x2616)
Pulse counting frequency
C05.27 (0x261B)
Motor encoder Z-pulse detection
times
C05.23 (0x2617)
X7 pulse counting
C05.28 (0x261C)
Motor encoder Z pulse cumulative
error
C05.24 (0x2618)
X7 pulse counting frequency
C05.29 (0x261D)
Motor encoder frequency (PU)
Table 4-50
4.16 Terminal input / Output Function Selection
X
Function explanation
X
Function explanation
X
Function explanation
0
No function
29
PID feedback switching 3
58
Run output blocking command
1
Forward running
30
Program running (PLC) pause
59
Reserved
2
Reverse running
31
Program running (PLC) reboot
60
Speed-torque control switching
3
Three-wire running control
(Xi)
32
Acceleration/deceleration
time
setting terminal 1
61
Rigid tapping / pulse position control
4
Forward jogging
33
Acceleration/deceleration
time
setting terminal 2
62
Reserved
5
Reverse jogging
34
Acceleration/deceleration pause
63
Reserved
6
Free stop
35
Swing frequency input
64
Zero-servo command
7
Emergency stop
36
Swing frequency pause
65
Reserved
8
Fault reset
37
Swing frequency reset
66
Reserved