SD500 Spindle Servo Drive Manual
21
Note:
Use the keyboard move key to quickly select the tens, hundreds and thousands bits of the modified parameter values.
●
Check monitoring status
SET
Given
frequency
Output
frequency
Output current
Bus voltage
SET
SET
SET
Figure 3-3
Note:
When using the external keyboard, use the left move button to cycle through the first row of monitoring parameters, and use the right
move button to cycle through the second row of monitoring parameters.
●
Check monitoring parameters
The following is an example of checking C02.05 [PLC running phase] to illustrate the basic LED operator.
MOD
press
MOD press
SET
SET
SET
MOD long press
Up
Down
Up
Down
Figure 3-4
●
Motor Self-learning
To deliver the best control performance, self-learning of motor running system parameters under vector control need self-learning. Please
refer to the following figure for the self-learning process. Please select rotary self-learning for the first time, and make sure the motor is in
no-load or light-load state during the self-learning process.
Up/Down keys to modify the modes
F02.07=1: rotary self-learning
F02.07=2: stationary self-learning
F02.07=3: stator resistance self-learning
F02.07=6: encoder self-learning
SET
SET
Long press SET for
1s to start self-learning
F02.07=1/2/3
F02.07=6
Self-learning completed
Figure 3-5