SD500 Spindle Servo Drive Manual
8
d)
The spindle drive needs to be mounted on a flame-retardant surface to ensure enough space for heat dissipation. The mounting surface needs
reliably bear the weight of the spindle servo drive, otherwise there is a possibility of personnel injury or equipment damage if it falls.
e)
When the spindle drive is installed near a vibration source, please install vibration isolators on the mounting surface of the servo unit to
prevent vibration from being transmitted to the servo unit.
f)
Install the spindle servo drive away from sources of electromagnetic interference.
2.1.3 Spindle Drive Installation Space Requirements
Heat generated from SD500 spindle servo drive is distributed in a bottom-up way, the spindle servo drive must be installed in the following
vertical way (see Figure 2-1), and other components in the cabinet should be taken consideration to ensure that the SD500 spindle drive has
enough space for heat dissipation. Multiple spindle servo drives are usually installed side by side, and the installation space requirements are
shown in the figure below as well. In cases where the drives are mounted above or below, it is highly recommended to install thermal deflectors
between the drives.
Figure 2-2
2.2 Electrical Installation