107
inverter operates according to this
frequency;
13
Exterior fault alarm
Input port of exterior fault signal
14
Acceleration/deceleration
time selection terminal 1
See the below fig.
15
Acceleration/deceleration
time selection terminal 2
16
Frequency main channel
selection terminal 1
When [ E-02 ] selection is “ 12 ”,
frequency input main channels are
selected by the0 terminals; Four
terminals can combinated out 0~11,
separately corresponding to the[E-02]
0~11 frequency input channels;
17
Frequency main channel
selection terminal 2
18
Frequency main channel
selection terminal 3
19
Frequency main channel
selection terminal 4
20
Program operation pause
During the program running, if this
signal is valid, enable the program
running pause, frequency inverter
output as 0, after signal disappear,
frequency inverter continue operate
according to the state before pause;
21
Program restart
During the program running, if this
signal is valid, it enables the
program running restart, starting to
run from the first stage;
22
Timer trigger terminal
Terminal for start timer to record,
see[F-38]
23
Timer reset terminal
Clear the time records of the timer
24
Counter reset terminal
Clear the time records of the counter
25
Counter clock input terminal see[F-39、F-40]
Acceleration/deceleration time selection check list
Содержание AC60 series
Страница 1: ...Manual AC60 series frequency inverter Version V2 0...
Страница 30: ...26...
Страница 44: ...40 2 Double display keyboard cycle switch the display of monitoring parameter mode...
Страница 46: ...42 2 Double display keyboard parameter setting mode...
Страница 162: ...158 8 2 2 Over current...
Страница 163: ...159 8 2 3 Over voltage...
Страница 164: ...160 8 2 4 Supply voltage is too low...
Страница 165: ...161 8 2 5 Inner inverter over heat...
Страница 166: ...162 8 2 6 Over load...
Страница 167: ...163 8 2 7 No display 8 2 8 Motor heat...
Страница 168: ...164 8 2 9 Motor does not rotate...