115
frequency of frequency inverter is lower
than the frequency detection level, it
outputs invalid signal after [F-35] delay
time setting.
5
Running
When frequency inverter is in the running
state, it outputs signal.
6
Reversal running
When frequency inverter reverse,it outputs
signal.
7
Inverter
undervoltage
When the frequency inverter displays “LU”
for the voltage is too low,it outputs signal.
8
Overload
pre-alarming
When the output current of frequency inverter
reach[F-36]and[F-37]setting values,it
outputs signal.
9
Output
frequency
reach upper limit
frequency
When frequency inverter run to the upper
frequency limit, it outputs signal.
10
Output
frequency
reach lower limit
frequency
When frequency inverter run to the lower
frequency limit,it outputs signal.
11
Exterior fault stop
When the exterior fault input signal of
frequency inverter is valid, and the
frequency inverter stoppes, this terminal
outputs valid signal.
12
Timer times up
When reaching the setting time of frequency
build-in timer , this terminal output a 500ms
wide valid pulse signal.
13
Counter
reach
maximum values
When the counter reaching the maximum values,
output terminal output a valid signal with
width equal to exterior clock period. And the
Содержание AC60 series
Страница 1: ...Manual AC60 series frequency inverter Version V2 0...
Страница 30: ...26...
Страница 44: ...40 2 Double display keyboard cycle switch the display of monitoring parameter mode...
Страница 46: ...42 2 Double display keyboard parameter setting mode...
Страница 162: ...158 8 2 2 Over current...
Страница 163: ...159 8 2 3 Over voltage...
Страница 164: ...160 8 2 4 Supply voltage is too low...
Страница 165: ...161 8 2 5 Inner inverter over heat...
Страница 166: ...162 8 2 6 Over load...
Страница 167: ...163 8 2 7 No display 8 2 8 Motor heat...
Страница 168: ...164 8 2 9 Motor does not rotate...