45
E-06
Keyboard
first
display monitoring
selections:
0:Given frequency
1:Output frequency
2:Output current
3:Input voltage
4:Output voltage
5:Mechanical speed
6:PID given value
7:PID feedback value
0
●
72
106H
E-07
Keyboard
second
display monitoring
selections:
1
●
72
107H
E-08
Keyboard REV/JOG
key
function
options
0:REV
1:JOG
0
●
72
108H
E-09
Maximum frequency
0.50~400.0Hz
50.0
〇
73
109H
E-10
Upper limit of
frequency
Upper
limit
of
frequency
~
Maximum
frequency
50.0
●
73
10AH
E-11
Lower limit of
frequency
0.00 ~ Upper limit of
frequency
0.00
●
73
10BH
E-12
Lower
limit
frequency running
mode
0:stop
1:run according to lower
limit frequency
0
●
73
10CH
E-13
Acceleration time
1
0.1~6500.0 second
※
●
74
10DH
E-14
Deceleration time
1
0.1~6500.0 second
※
●
74
10EH
E-15
Acceleration
、
Deceleration mode
0:Straight line
1:S Curve
0
●
75
10FH
E-16
Keyboard
number
given frequency
Lower limit frequency ~
Upper limit frequency
50.0
●
76
110H
E-17
V/F mode
0:Constant torque curve
1 : Drop torque curve
1(1.5times)
2 : Drop torque curve
2(1.7times)
3 : Drop torque curve
3(2.0times)
4:Auto-defined curve
0
〇
76
111H
E-18
Torque upgrade
0.0%:auto
0.1%~25.0%
※
●
76
112H
Содержание AC60 series
Страница 1: ...Manual AC60 series frequency inverter Version V2 0...
Страница 30: ...26...
Страница 44: ...40 2 Double display keyboard cycle switch the display of monitoring parameter mode...
Страница 46: ...42 2 Double display keyboard parameter setting mode...
Страница 162: ...158 8 2 2 Over current...
Страница 163: ...159 8 2 3 Over voltage...
Страница 164: ...160 8 2 4 Supply voltage is too low...
Страница 165: ...161 8 2 5 Inner inverter over heat...
Страница 166: ...162 8 2 6 Over load...
Страница 167: ...163 8 2 7 No display 8 2 8 Motor heat...
Страница 168: ...164 8 2 9 Motor does not rotate...