background image

 

60

selection  

H-30 

Upper limit 
demarcative values 

lower limit 
demarcative  values ~
100.0% 

100.0

141 

31EH 

H-31 

lower limit 
demarcative value 

0.0%~Upper limit 
demarcative values 

0.0 

141 

31FH 

H-32 

Program run mode  

0:single cycle (time in 
seconds) 
1 : continuous  cycle 
(time in seconds) 
2:single cycle, 
continuous running 
(time in seconds) 
3:single cycle (time in 
minute) 
4 : continuous  cycle 
(time in minute) 
5:single cycle, 
continuous running 
(time in minute) 

141 

320H 

H-33 

Program 
breakpoint restore 
mode selection 

0:operation according 

to  the  first  step 
speed  

1:re-timing and 
 running according  
to the be interrupted
 running frequency  
2:running according to 
the residue time after
 being interrupted 
 running frequency 

143 

321H 

H-34 

In  program  run  
state,power 

off 

storage selection  

0 : Power  off  without 
storage  
1 : Power  off  with 
storage 

143 

322H 

H-35 

 First  step  speed 
direction 

and 

ace&dece time 

0:Forward Rotating;
acceleration time 
 1/deceleration time 1
1:Forward Rotating;
acceleration time 
 2/deceleration time 2
 

145 

323H 

H-36 

Second  step  speed 
direction 

and 

ace&dece time 

145

 

324H 

H-37 

Third  step  speed 

145

 

325H 

Содержание AC60 series

Страница 1: ...Manual AC60 series frequency inverter Version V2 0...

Страница 2: ...fic industrial application AC60 series adopts G P all in one design which facilitates users in choosing and use the proper model This manual is the supporting data sheet for AC60 This instruction manu...

Страница 3: ...nting direction and space 14 3 4 Dismantle and install tail hood 15 3 5 Dismantle and install keyboard 16 3 6 Installation size 17 3 7 Operation keyboard size 22 Chapter four Frequency Inverter Wiring...

Страница 4: ...ce 165 9 1 Inspection and maintenance 165 9 2 Components needed periodic replace 166 9 3 Preservation and maintenance 167 9 4 Measurement and judgment 167 Chapter ten Optional parts 169 10 1 Alternati...

Страница 5: ...t will cause danger of light injuries or equipment destruction while operating against the rules Note some information is useful while operating and use frequency inverter 1 2 Safety requirements and...

Страница 6: ...ttention to the installing place to guarantee the effective heat dissipation 2 When carrying the frequency inverter please support its bottom Wiring Danger 1 Wire is connected only when the main circu...

Страница 7: ...etc No touch the printed circuit boards IGBT or other internal devices without anti static measures otherwise it will cause the malfunction of frequency inverter 5 Please don t connet phase shifter c...

Страница 8: ...sed by booster from low to high Otherwise it will damage the frequency inverter Attention 1 Check all periphery fittings are wired properly according to the handbook Otherwise it will cause accidents...

Страница 9: ...t will cause electric shock Maintenance Danger 1 Please don t maintain and repair the equipment with electric Otherwise it will cause electric shock 2 Before maintaining and repairing the frequency in...

Страница 10: ...the load equipment mechanical resonance To avoid it you can set up jumping frequency 7 As output voltage of the inverter is pulse wave type if there is capacity which can improve power factor or press...

Страница 11: ...ter please pay attention to 1 Electrolytic capacitor the electrolytic capacitor of main circuit or the printing plate may explode when they are burned 2 Plastic plastic incineration may generate toxic...

Страница 12: ...ies frequency inverter have undergone a rigorous testing and quality control before leaving the factory Please check all of qualified certification product manual and warranty cards 4 Please check the...

Страница 13: ...que specifications Items Specifications Pow er Voltage frequency Single phase 220V 50 60Hz Three phase 220V 50 60Hz Three phase380V 50 60Hz Three phase660V 50 60Hz Three phase 1140V 50 60Hz Allowable...

Страница 14: ...V F Automatic energy savin g operation According to the load conditions automatic optimize the V F curves to implement energy saving operation Standard functions PID control Acceleration and decelera...

Страница 15: ...motor speed PID feedback quantitative PID module temperature input and output terminal Fault Overvoltage undervoltage overcurrent short circuit phase missing overload heat pressure stall current limi...

Страница 16: ...75 45 25 45 160 90 52 31 55 200 110 63 38 75 260 150 86 52 93 320 180 98 58 110 380 210 121 75 132 420 250 150 86 160 550 310 175 105 185 600 340 198 115 200 660 380 218 132 220 720 415 235 144 250 47...

Страница 17: ...rom heat sources 3 Inverter installed under the altitude of 1000m can output rated power It needs be derated to use when the altitude is more than 1 000 m Pls refer specific figures as below 4 Humidit...

Страница 18: ...e and components titles 3 3 Mounting direction and space Frequency inverter should be installed in a well ventilated indoor place and adapt wall mounted or closet style vertical installation Enough sp...

Страница 19: ...the uniformity of each frequency inverter heat dissipation While it adopts vertical juxtaposition installation you should install deflector plate to avoid the heat of below inverter flows through the...

Страница 20: ...ial dismantlement hole design Put your fingers into the hole upwardly pull the cover with a little force until the buckle between the tail hood and the crust tear off and then removed tail hood down 3...

Страница 21: ...17 Dismantlement Put your finger into the keyboard dismantlement hole and pull the keyboard out 3 6 Installation size units mm 3 6 1 Installation size of machine with plastic cover...

Страница 22: ...S2 R40G 122 112 182 171 154 5 145 5 AC60 S2 R75G AC60 S2 1R5G AC60 T3 R75G 1R5P AC60 T3 1R5G 2R2P AC60 T3 2R2G 3R7P AC60 S2 2R2G 159 147 2 246 236 157 5 148 5 5 AC60 S2 3R7G AC60 T3 3R7G 5R5P AC60 T3...

Страница 23: ...AC60 T3 015G 018P 238 180 390 377 212 7 AC60 T3 018G 022P 281 200 496 476 256 9 AC60 T3 022G 030P AC60 T3 030G 037P AC60 T3 037G 045P 353 200 600 578 286 11 AC60 T3 045G 055P AC60 T3 055G 075P 380 300...

Страница 24: ...PRG RESET STOP JOG REV FWD RPM RPM V A V A H z H z bottom entering line hole back entering line hole Frequency inverter G Constant torque load P Fans pump load H H1 L L1 W W1 W2 D E A1 B1 C AC60 T3 09...

Страница 25: ...ection which consist the cabinet machine installed directly in installation slot or ground 3 6 4 Cabinet style machines installation size Frequency inverter G Constant torque load P Fans pump load W W...

Страница 26: ...22 3 7 Operation keyboard size 3 7 1 Single display keyboard size 86 7 56 7 16 22 2 84 2 35 1 17 1 17 5 54 2 3 7 2 Double display keyboard size 60 6 110 6 16 18 6 63 8 113 8 37 56 2 19...

Страница 27: ...heral equipment filter reactor of inverter are installed the first step is use the 1 000 volts M megger to measure the grounding insulation resistance to ensure it not less than 4 M 6 Can not install...

Страница 28: ...ially between the parallel cables that extend for long distance When signal cables have to pass through the power cables they should be orthogonal crossing 11 Main circuit wiring and wire diameter spe...

Страница 29: ...loads such as electromagnetic relays contactors etc surge voltage absorption circuit should be added such as RC absorption circuit be careful that the leakage current should be lower than the control...

Страница 30: ...26...

Страница 31: ...als E W T3 V T2 U T1 T L3 S L2 R L1 PB 4 3 4 AC60 series three phase 380V T3 18G 22P 75G 093P machine main circuit terminals P1 R S T U V W POWER INPUT MOTOR OUTPUT 4 3 5 AC60 series three phase 380V...

Страница 32: ...Terminal name Functions description L Single phase AC 220V power input terminal N R Three phase AC power input terminal S T E Earth terminal P1 Terminals for external DC inductor PB Terminals for exte...

Страница 33: ...037G 045P 75 37 80 150 25 AC60 T3 045G 055P 90 45 100 200 30 AC60 T3 055G 075P 110 55 180 225 30 AC60 T3 075G 093P 150 75 180 300 50 AC60 T3 093G 110P 180 93 250 350 50 AC60 T3 110G 132P 210 110 250 4...

Страница 34: ...connect with COM is workable X1 Multifunction input terminalsX1 Short connect with COM is workable Multifunction input terminals please refere to parameters F 01 F 06 to set the definitions by progra...

Страница 35: ...ary power 24 Power anode terminals Maximum output 24V 200mA COM Common terminal Commu nicat ion A Communication Interface RS485 Communication Interface B Communication Interface 4 6 RS485 communicatio...

Страница 36: ...there are a group of jumper terminals J1 J2 and J3 which is chose to work with software to decide A02 output mode Usage details are shown in the following fig Jumper name Details specification J1 Term...

Страница 37: ...33 4 7 Backup circuit If the frequency inverter emergence break off for fault it will cause great loss or other unexpected fault occurred Please add this circuit standby to ensure safety...

Страница 38: ...standby or running press for 1 sec to enter monitorning interface Confirm modify key Press to modify parameter while in menu interface Press again to confirm aftr modify While standby or running pres...

Страница 39: ...OG Stop Reset key Machine stops if press it while run stop is controlled by keyboard Its efficiency range is defined via function no F 07 Inverter reset if press it in fault state no reset if fault is...

Страница 40: ...digits modified by up dowm key Change LED monitoring items while standby or running Forward key While run stop is controlled by keyboard press this key the inverter forward rotate Jog Reverse key Whi...

Страница 41: ...When Hz indicator and the A indicator light at the same time the 4 digit digital display value is the motor speed Flash ing When the A indicator and the V indicator flashing at the same time the 4 dig...

Страница 42: ...is given PID On 4 digit digital display value is the amount of feedback of PID State indic ating lamp FWD On Frequency inverter turn forward FWD flashi ng Frequency inverter reverse FWD Off Frequency...

Страница 43: ...lay various monitoring parameters by the LED nixie light Inverter with two kinds of keyboard both can set the concrete display parameters by E 06 E 07 under stopping state or operation state They both...

Страница 44: ...40 2 Double display keyboard cycle switch the display of monitoring parameter mode...

Страница 45: ...parameters F 08 modification as an example as follow Terminal operational control mode is changed from the standard operational control mode to the second line style operational control mode to introd...

Страница 46: ...42 2 Double display keyboard parameter setting mode...

Страница 47: ...r NO Function description Range of settings and definition Factory setting Modify limitation Reference page Communicat ion code E 01 Run command given channel selection 0 Keyboard control 1 Terminal c...

Страница 48: ...0 69 103H E 04 Frequency given channel gain 0 01 5 00 1 00 71 104H E 05 Frequency given channels combinations mode 0 Main channel valid auxiliary channel invalid 1 Auxiliary channel valid main channe...

Страница 49: ...0 73 10AH E 11 Lower limit of frequency 0 00 Upper limit of frequency 0 00 73 10BH E 12 Lower limit frequency running mode 0 stop 1 run according to lower limit frequency 0 73 10CH E 13 Acceleration...

Страница 50: ...digit reserved 0000 79 115H E 22 Slip frequency compensation 0 200 0 80 116H E 23 Energy saving running options 0 Invalid 1 Valid 0 81 117H E 24 Voltage auto adjustment function 0 Invalid 1 Global va...

Страница 51: ...0 0 10 0 second 0 0 87 126H E 39 Jumping frequency 1 0 00 400 0Hz Fmax 0 00 88 127H E 40 Jumping frequency 2 0 00 400 0Hz Fmax 0 00 88 128H E 41 Jumping frequency 3 0 00 400 0Hz Fmax 0 00 88 129H E 42...

Страница 52: ...valid 1 valid LED 1000 digit inverter over loading and over temperature protection options 0 free close down 1 current limiting running 0 1 1 93 131H E 50 Electronic heat sensitive coefficient setting...

Страница 53: ...0 99 13DH E 62 Speed tracking stability time 0 20 10 00 second 0 60 99 13EH E 63 Parameters change protection 0 all parameters can be changed 1 only keyboard numbers setting can be change 2 all the pa...

Страница 54: ...tep speed contol4 9 ascend descent running frequency UP 10 ascend descent running frequency DW 11 trilinear operation mode control 12 PID control cancel 13 exterior fault alarm 14 acceleration and dec...

Страница 55: ...23 timer reset terminal 24 timer Auto Nulling terminal 25 Counter clock input terminal F 07 Input signal action mode selection LED 0 digit free close down restore mode 0 after the disconnection resto...

Страница 56: ...art directly 1 terminal control first close down before startup F 08 Terminal operation control mode selection 0 standard operation control 1 double line operation mode control 2 trilinear operation m...

Страница 57: ...215H F 22 14 step speed setting 14X 45 00 111 216H F 23 15 step speed setting 15X 50 00 111 217H F 24 Acceleration time2 0 1 6500 0 second 113 218H F 25 Deceleration time2 113 219H F 26 Acceleration...

Страница 58: ...st down 12 timer times up 13 Counter reach maximum value 14 Counter reach setting value 15 PID feedback quantity upper limit alarm 16 PID feedback quantity lower limit alarm 17 sensor disconnect 18 pr...

Страница 59: ...limit 10 0V F 45 0 0 120 22CH F 45 VS2 terminal input voltage upper limit F 44 10 0V 10 0 120 22DH F 46 VS2 terminal input Voltage gain 0 01 5 00 1 00 120 22EH F 47 VS2 terminal input Zero offset 1 00...

Страница 60: ...eristics selection LED 0 digit VS1 input characteristic selection 0 positive characteristic 1 negative characteristic LED 10 digit AS input Characteristic selection 0 positive characteristic 1 negativ...

Страница 61: ...3 AO1 output signal gain 25 200 100 128 23FH F 64 AO2 output signal gain 25 200 100 128 240H F 65 AO1 output signal zero adjustment 10 0 10 0 0 129 241H F 66 AO2 output signal Zero adjustment 10 0 10...

Страница 62: ...e setting frequency F3 H 04 H 08 25 00 131 306H H 07 Free setting voltage V4 H 05 H 09 75 0 131 307H H 08 Free setting frequency F4 H 06 H 10 37 50 131 308H H 09 Free setting voltage V5 H 07 100 0 100...

Страница 63: ...0 0 100 0 136 312H H 19 Proportion gain P 0 1 100 0 20 0 137 313H H 20 integral time I 0 1 100 0 second 2 0 137 314H H 21 Differential gain D 0 0 10 0 0 0 137 315H H 22 Sampling period 0 01 60 00 seco...

Страница 64: ...3 Program breakpoint restore mode selection 0 operation according to the first step speed 1 re timing and running according to the be interrupted running frequency 2 running according to the residue t...

Страница 65: ...eed direction and ace dece time 5 145 328H H 41 Seventh step speed direction and ace dece time 6 145 329H H 42 Eighth step speed direction and ace dece time 7 145 32AH H 43 Ninth step speed direction...

Страница 66: ...H 60 11th step speed operation time T11 10 0 147 33CH H 61 12th step speed operation time T12 10 0 147 33DH H 62 13th step speed operation time T13 10 0 147 33EH H 63 14th step speed operation time T...

Страница 67: ...71 Communications timeout time 0 0 6500 0 second 10 0 150 347H H 72 RS485 Communication disconnection action mode 0 close down 1 Continued operation 0 150 348H H 73 Response delayed 0 001 1 000 secon...

Страница 68: ...rection of the frequency inverter is control by whether connect the control terminal Forward Rotating FWD or reverse REV to COM or not 2 RS485 Communication The operation stop and direction of the fre...

Страница 69: ...rminal VS2 voltage signal and program control channel will also directly control the operation direction of the frequency inverter When restoring the factory settomg the parameter values will not be c...

Страница 70: ...al The given frequency of the main channel is determined and amended by the pulse signal input of the control terminal PUL If you want more detail about the input analog quantity and the corresponding...

Страница 71: ...hannel and the running direction of the frequency inverter is controlled by the process of simple PLC which inside the frequency inverter maximum process control is 15 steps speed Details sees paramet...

Страница 72: ...ece acce time This function is particularly compliant to the system of the textile industry in which the rotational speed changes according to the diameter difference between the before and behind cop...

Страница 73: ...se to select the auxiliary input channels of the give frequency If you need more details about the combination method of the auxiliary channel and the main channel please refer to E 05 0 Keyboard numb...

Страница 74: ...1 X6 can separately be defined as frequency ascending terminal and descending terminal please refer to parameter F 01 F 06 for more detail For the initial frequency mode setting in ascend and descend...

Страница 75: ...auxiliary channel by proportion Frequency given channel combination are used to select the constitution method of main frequency input channel and auxiliary channel of the frequency inverter And K re...

Страница 76: ...eps speed operation auxiliary channel can not be conbined E 06 Upper LED display selection Range 0 7 Factory setting 0 E 07 Lower LED display selection Range 0 7 Factory setting 1 Apart used to choose...

Страница 77: ...mum frequency Factory setting 50 0 E 11 Lower frequency limit Range 0 00 Upper frequency limit Factory setting 0 00 E 12 Lower frequency limit operation mode Range 0 1 Factory setting 0 Maximum freque...

Страница 78: ...ncy upper frequency limit and lower frequency limit is shown as the follow fig Attention the lower frequency limit range is invalid for jog frequency operation Only the upper frequency limit range is...

Страница 79: ...eration time is only valid for normal speed up barring start DC braking time and start up frequency duration Deceleration time is only valid for the normal speed down barring stop DC braking time If y...

Страница 80: ...te in short time while high frequency E 16 Keyboard number given frequency Range lower frequency limit upper frequency limit Factory setting 50 0 When frequency given channel is keyboard number given...

Страница 81: ...ue curve 2 0 time 4 auto definition curve In this state operation by the auto definition curve E 18 function invalid users can set appropriate V F curves according to the load characteristics see H 01...

Страница 82: ...ine generates large heat while efficiency decreased and effort reduced Meanwhile radio interference is large Another question of high carrier frequency operation is capacitive leakage current increasi...

Страница 83: ...n 36 lf long term work in the low frequency frequency inverter are proposed to reduce the carrier frequency to reduce the impact of the dead time E 21 Carrier characteristic Range 0000 1111 Factory se...

Страница 84: ...um of inverter output voltage evenly distributing in a wide frequency range to inhibit the electrical noise and vibration effectively LED 1000 digit Reserved E 22 Slip frequency compensation Range 0 0...

Страница 85: ...in deceleration The output voltage automatic control function is the AVR function When the AVR function is invalid the output voltage changes along with the input voltage change When AVR function is...

Страница 86: ...by the operation order channles the other jog orders only when it is the same with the operation order channel have the priority Such as the keyboard jog operation is valid only when the keyboard con...

Страница 87: ...ituation with big static friction torque and small load inertia or the situation where it need to coordinate with exterior machinery braking devices That is occasion where the motor shaft can maintain...

Страница 88: ...to restart function is strictly prohibited to use It can not restart until it totally stops It also can restart by start up frency after DC braking Tips In normal FOR REV swich process or acceletation...

Страница 89: ...requency inverter will out of the speed track to restart mode Attention the power cut restart function enables the frequency inverter automatic start operation after power on Therefore there is huge c...

Страница 90: ...n DC braking function is seleced the output frequency of frequency inverter will jump to zero and the frequency inverter will stop work after the DC braking finished Otherwise the frequency inverter w...

Страница 91: ...n provide 0 speed torque Normally it is used to enhance the stop accuracy and fulfill quick stop but it can not be used in the deceleration braking in normal operation Once start DC braking frequency...

Страница 92: ...etting 0 00Hz E 40 Jump frequency 2 Range 0 00 400 0Hz Factory setting 0 00Hz E 41 Jump frequency 3 Range 0 00 400 0Hz Factory setting 0 00Hz E 42 Jump frequency range Range 0 00 5 00Hz Factory settin...

Страница 93: ...rter will normally overlap the jumping frequency district Do not set three overlap or nested jumping frequency ranges 2 Jumping frequency is valid for jog multi step speed and swing frequency operatio...

Страница 94: ...k to restart If the frequency inverter can not succeed restore operation within the setting times then frequency inverter will start fault protection and stop output Fault auto restore can be most set...

Страница 95: ...the default direction Actual rotation direction is the same with the requirement The actual direction will not be adjusted 1 Opposite to the default direction Actual rotation direction is opposite to...

Страница 96: ...for the devices with large inertia load and dead zone when change the direction E 48 Cooling fan running options Range 0 1 2 Factory setting 1 Be used to select the fan running mode 0 After frequency...

Страница 97: ...e of cooling fans E 49 Frequency protection mode selection Range 0000 1111 Factory setting 0 11 LED 0 digit over voltage stall protection selection 0 Invalid 1 Valid When the frequency inverter decele...

Страница 98: ...er will report Err1 and stop output The motor free stops And fault output terminal will act This function is valid only for 7 5P or above power machine of AC60 series The factory setting of this param...

Страница 99: ...load It can be set as 100 If the rated current of motor with load does not match the rated current of the inverter right thermal relay protection to motor will be set by this parameter The factory set...

Страница 100: ...ducing output frequency to prevent the fault trip which caused by excessive currents This function is especially suitable for some loads with larger inertia or drastic change The fiducial value of thi...

Страница 101: ...ter DC bus voltage rises and excesses the frequency rated voltage E 53 setting frequency inverter energy consumed braking starts to act The voltage of frequency inverter has to be 20V lower than the E...

Страница 102: ...tage protection value Range 60 90 Factory setting 78 This parameter stipulates lower voltage limit of the DC side during the frequency inverter works normally In partial situations where power supply...

Страница 103: ...ge frequency inverter rated output voltage frequency output voltage ratio E 61 G P modules setting Range 0 1 Factory setting 0 When reset the factory setting this parameter setting values will not be...

Страница 104: ...eable Except for the keyboard number given frequency and keyboard number PID given quantitative parameter any other parameter can not be changed 2 All the parameter prohibit being changed All the para...

Страница 105: ...he state monitoring Monitorin g code Content Units Communicati on code C 1 Given frequency 0 01HZ C01H C 2 Output frequency 0 01HZ C02H C 3 Output current 0 1A C03H C 4 Input voltage V C04H C 5 Output...

Страница 106: ...C11H C 18 Terminal VS2 input value 0 1v C12H C 19 Terminal pulse input value C13H C 20 Counter record C14H C 21 DC bus voltage V C15H C 22 Analog output A01 0 01V C16H C 23 Frequency voltage current o...

Страница 107: ...de Er 01 The latest fault information For details pls see fault information code table E01H Er 02 The cumulative running time before the latest fault Units hour E02H Er 03 Output frequency while the l...

Страница 108: ...le the latest fault See above chart E0CH Er 13 The latest one fault information E0DH Er 14 The latest two fault information E0EH Er 15 The latest three fault Information E0FH Fault information code ta...

Страница 109: ...not note 21 LIFE Reserved Seek the technical support fault annal will not note 22 93SE Storage fault fault annal will not note 7 2 External terminal parameters detailed description F 01 Input signal s...

Страница 110: ...d commands input port The code combination realizes 15 steps of speed The multi steps speed commands has priority only next to the jog command 6 Multi steps speed control 2 7 Multi steps speed control...

Страница 111: ...nel selection terminal 3 19 Frequency main channel selection terminal 4 20 Program operation pause During the program running if this signal is valid enable the program running pause frequency inverte...

Страница 112: ...p terminal disconnect after connect LED 10 digit Ascending descending terminal control initial frequency setting 0 After operation adjust as UP DW terminal without frequency record after power off 1 A...

Страница 113: ...rectly 1 Terminal control to power off firstly then start Attention when the frequency inverter fault alarms three running order given channels can send valid reset signal to the frequency inverter If...

Страница 114: ...d at pulse edges K is the operation direction selection button D X is the multi function terminal X1 X6 are defined as the terminals of the three linears operational control 11 function F 09 1 step sp...

Страница 115: ...e 0 00Hz upper limit frequency Factory setting 45 0Hz F 18 10 step speed setting 10X Range 0 00Hz upper limit frequency Factory setting 50 0Hz F 19 11 step speed setting 11X Range 0 00Hz upper limit f...

Страница 116: ...refer to H 65 If there is wrong setting frequency inverter will report fault Err5 Tips 1 multi step speed running are not limited by the lower frequency limit but are sill limited by the upper frequen...

Страница 117: ...4 Rang 0 1 6500 0 second Factory setting second F 29 Deceleration time 4 Rang 0 1 6500 0 second Factory setting second During swing frequency control it needs to define the acceleration deceleration t...

Страница 118: ...nal 3 Frequency arriving detection When the output frequency of frequency inverter reaches or gets close to a certain range of the given frequency this range determined by the parameter F 33 the outpu...

Страница 119: ...ignal 9 Output frequency reach upper limit frequency When frequency inverter run to the upper frequency limit it outputs signal 10 Output frequency reach lower limit frequency When frequency inverter...

Страница 120: ...dback quantity reaching the alarming lower limit H 27 it outputs signal 17 Sensor disconnect While the frequency inverter detects the feedback signal in PID control mode if the feedback signal is smal...

Страница 121: ...outputs signal When the output frequency is lower than F 34 setting values by the delay time parameter F 35 setting it outputs signal F 36 Overload pre alarm level Range 50 200 Factory setting 150 F...

Страница 122: ...ue Range 0 1 65000 second Factory setting 1 second This parameter is used to time for the frequency inverter The timer start up is accomplished by the exterior trigger terminal of the timer trigger te...

Страница 123: ...ignal is input When the count value to the exterior clock reaches F 40 setting value in the corresponding output terminal it outputs a valid signal While it reached F 39 and the counter clear to zero...

Страница 124: ...ory setting 0 00V F 45 VS2 terminal input voltage upper limit Range F 44 10 00V Factory setting 10 00V F 46 VS2 terminal input voltage gain Range 0 01 5 00 Factory setting 1 00 F 47 VS2 terminal input...

Страница 125: ...y of frequency inverter is determined by the absolute value of amplitude of the input voltage of terminal VS2 While output phase sequence machine direction is determined by the polar of the input volt...

Страница 126: ...cy of another channel It carries out signed calculation while combination If the result is positive machine runs according to E 01 gived direction If the result is negative the output frequency is 0 B...

Страница 127: ...actory setting 4 00mA F 51 AS terminal input current upper limit Range F 50 20 00mA Factory setting 20 00mA F 52 AS terminal input current gain Range 0 01 5 00 Factory setting 1 00 AS terminal input c...

Страница 128: ...ut frequency gain Range 0 01 5 00 Factory setting 1 00 Terminal input frequency lower limit This function defines the minimum frequency which received by the analog input terminal PUL Frequency invert...

Страница 129: ...aracteristic Tips when VS2 opens bipolar function F 48 is set as 1 or 2 this parameter is invalid LED kilo digit Impulse input characteristic selection 0 Positive characteristic 1 Negative characteris...

Страница 130: ...filtering time is the stronger anti interfere ability is but the respond speed slow down The shorter filter time is the weaker anti interfere ability is but the respond speed become faster F 60 Outpu...

Страница 131: ...4 PID given quantity 5 PID feedback quantity 6 DC bus voltage 7 Output voltage Tips when AO2 port is frequency pulse output or 4 20mA output 0 corresponding output quantity is not zero F 62 AO2 output...

Страница 132: ...isconnect the J1 J3 When select 0 10V output mode pls short connect the J3 disconnect the J1 J2 When frequency inverter leaving factory both software and hardware are defaulted as frequency pulse outp...

Страница 133: ...defines the maximum signal which received by the keyboard potentiometer Frequency inverter will automatically filters the signal whose value is upper than this value Keyboard potentiometer gain This...

Страница 134: ...taneous frequency at stop in ascend descend process which can be reviewed or modified after stop When the F 07 LED 10 digit is set 2 user can preset the initial output frequency for frequency inverter...

Страница 135: ...etting 25 00Hz H 07 Free setting voltage V4 Range H 05 H 09 Factory setting 75 0 H 08 Free setting frequency F4 Range H 06 H 10 Factory setting 37 50Hz H 09 Free setting voltage V5 Range H 07 100 0 Fa...

Страница 136: ...rocess control By series calculation on the difference between the feedback quantity of controlled object and the frequency PID given quantity such as proportion integral differential and so on it adj...

Страница 137: ...equency while the PID feedback quantity is greater than PID given quantity Such as central air conditioning constant control and pay off tension control While frequency inverter receiving the operatio...

Страница 138: ...ulse frequency signal 6 RS485 interface Given by the signal received by RS485 communication interface 0 Exterior exterminal VS1 feedback by exterior exterminal VS1 0V 10V analog signal 1 Exterior exte...

Страница 139: ...e 0 1 6500 0 second Factory setting 0 0 second This function is defined as this after PID running frequency inverter will accelerate to the PID preset frequency H 14 according to the acceleration dece...

Страница 140: ...100 0 Factory setting 100 0 This function is used to adjust the display data of PID given quantity and PID feedback quantity Actual LED display value given feedback signal value lower input limit sens...

Страница 141: ...ion effect When integral time is large it responds slowly Besides the control power to the exterior disturbance is getting weaker When integral is small it responds fast Frequency inverter will vibrat...

Страница 142: ...The shorter sampling period is the quicker it responds H 23 PID control deviation limit Range 0 0 20 0 Factory setting 0 0 It is the maximum offset of PID feedback quantity to PID given quantity When...

Страница 143: ...eshold and stand by the setting value for a while frequency inverter will start dormancy detection In the dormancy detection process if the feedback is higher than the dormancy threshold the output fr...

Страница 144: ...puts reaching signal This parameter is defined as percentage of the largest range of the sensor that the PID feedback quantity accounts for This function is only valid in using the constant PID contro...

Страница 145: ...the feedback sensor fault is deemed to be vanish and system restores PID closed loop control PID given quantity is restricted by this parameter in the range of upper lower limit demarcative value this...

Страница 146: ...is second 2 signal cycle continuous running time by second After finishing a single cycle running the frequency inverter does not close down It works on at the final step speed whose running time is n...

Страница 147: ...ncy inverter will continue to run as the breakpoint operation frequency and time again If selects the 2 mode frequency inverter will continue to run as the breakpoint operation frequency for the resid...

Страница 148: ...144 next time If need to ensure that after restoring from power down the frequency inverter continues the state before power down this parameter should be set as 1...

Страница 149: ...eration deceleration time Range 0 7 Factory setting 6 H 42 8 step speed direction and acceleration deceleration time Range 0 7 Factory setting 7 H 43 9 step speed direction and acceleration decelerati...

Страница 150: ...tion time 1 deceleration time 1 1 Forward acceleration time 2 deceleration time 2 2 Forward acceleration time 3 deceleration time 3 3 Forward acceleration time 4 deceleration time 4 4 Reverse accelera...

Страница 151: ...ed operation time T7 Range 0 0 6000 0 Factory setting 10 0 H 57 8 step speed operation time T8 Range 0 0 6000 0 Factory setting 10 0 H 58 9 step speed operation time T9 Range 0 0 6000 0 Factory settin...

Страница 152: ...leration deceleration time 1 When using the swing frequency running function frequency inverter will run for the acceleration deceleration time 1 to the f1 setting frequency then begin swing frequency...

Страница 153: ...ge control function it can control other AC60 frequency inverters synchro operation in the network H 67 This machine address Setting range 1 247 Factory setting 1 This parameter defines local communic...

Страница 154: ...ruction of superordination machine can be revised proportionally H 71 Communication overtime time Range 0 0 6500 0 second Factory setting 10 0 second If the gap time between a communication and the ne...

Страница 155: ...equency inverter receiving the data and responding data back to the superordinate machine If the response delay time is shorter than the system handling time the response time should according to the...

Страница 156: ...evice grounding line shield line grounding condition distance condition of terminals and control machine o C 1 Acc over current 1 Acc time is too short 2 Restart the machine in running when momentary...

Страница 157: ...2 Restart after the machine totally stop or set E 30 as 2 o U 2 Dec over voltage 1 Dec time is too short 2 Potential load or inertia is too big 3 Supply voltage overrun 1 Lengthen deceleration time 2...

Страница 158: ...Check E 57 setting 4 Adjust load or select and use frequency inverter with matching capacity grade 5 When requiring long term low speed work please use special motor for frequency inverter o L 2 Frequ...

Страница 159: ...rmal 1 check the supply voltage and troubleshooting 2 Ask for technical support LU2 Over voltage of supply power at running 1 Supply power is too low 2 Capacity of power network is too small or instan...

Страница 160: ...ed HALL component 1 Ask for technical support 2 Ask for technical support Err4 Frequency inverter exterior fault Exterior exterminal action Check exterior device Err5 Swing frequency running parameter...

Страница 161: ...157 2 EPROM is damaged LIFE Reserved 1 Ask for technical support 8 2 Common fault and processing methods 8 2 1 System fault...

Страница 162: ...158 8 2 2 Over current...

Страница 163: ...159 8 2 3 Over voltage...

Страница 164: ...160 8 2 4 Supply voltage is too low...

Страница 165: ...161 8 2 5 Inner inverter over heat...

Страница 166: ...162 8 2 6 Over load...

Страница 167: ...163 8 2 7 No display 8 2 8 Motor heat...

Страница 168: ...164 8 2 9 Motor does not rotate...

Страница 169: ...l ay LED display If display is abnormal Vision Affirm by the operation state At any time Cooli ng syste m Fan If there is abnormal vibration and abnormal noise Visual examination and listening No abno...

Страница 170: ...sults Pointer voltmeter is recommended to use to measure input voltage Rectifier voltmeter is recommended to use to measure output voltage Pliers galvanometer is recommended to use to measure input an...

Страница 171: ...circuit filter capacitor During charging user can use the pressure regulator to elevate slowly the input voltage of the frequency inverter to the rated input voltage The charging time should be above...

Страница 172: ...168 voltage due to being limited by the carry wave frequency disturbance and multimeter frequency response the read data which maybe inaccurate can be for reference only...

Страница 173: ...ng which the frequency converter produced and the short connection is not use noise filter electric capacitance case braking unit you can use when the moment can t meet to need It suit to the big iner...

Страница 174: ...f electromagnetic disturbance noise that produced by the frequency inverter and restrain the external radio interference as well as instantaneous impact and surging to this machine Filters should be a...

Страница 175: ...function pls also purchase the Veich braking units 10 4 Capacitance box This optional part is specially used in the occasion needing continue operation when power instantaneous failure lasts for a lo...

Страница 176: ...g paid service 11 3 The agency dealer provider can provide three guarantee service after being authorized by our company 11 4 When quality problems appears our company only undertakes three guarantee...

Страница 177: ...173 11 6 As for the three guarantee service the product must be returned back to our company and can only be replaced or mend after responsibility belonging confirmed...

Страница 178: ...s transfer information content and formats used in the serial communication Including host machine roll poling and broadcasting slave machine responsive format Content of the data frame of host machin...

Страница 179: ...y one equipment host machine can build up the protocol in the network can be called inquiry order Other equipments slave machines can only respond to the host machine inquiry order by providing data o...

Страница 180: ...essive order of the following transmission data domains slave machine address operation command code data and CRC checking bit Transmission byte of each domain is sexadecimal 0 9 A F Network equipment...

Страница 181: ...address domain ADDR Communication address 0 247 decimal 0 is broadcast address Function domain CMD 03H read slave machine parameter 06H write slave machine parameter 08H circuit auto detection Data d...

Страница 182: ...order 00H Data address 0102H low order 00H Data address 0103H high order 00H Data address 0103H low order 06H CRC CHK low order 89H CRC CHK high order 30H END Transmission time of 3 5 bytes RTU Slave...

Страница 183: ...K high order 96H END Transmission time of 3 5 bytes RTU Slave machine responding information normal START Transmission time of 3 5 bytes Slave machine address 02H Command code 06H Write data address h...

Страница 184: ...s Slave machine address 01H Command code 08H Detecting code high order 00H Detecting code low order 00H Data high order 13H Data low order 88H CRC CHK low order EDH CRC CHK high order 5DH END Transmis...

Страница 185: ...in ASCII mode 8 bits in RTU For instance the RTU character frame contains the following 8 bits 1 1 0 0 0 1 0 1 There are 4 bits with number 1 If using the even checking odd even checking bit of the fr...

Страница 186: ...es to minimum effective digit LSB is extracted to be detected If LSB is 1 the register independently XOR with the the preset value If LSB is 0 no XOR This entire process needs to repeat 8 times After...

Страница 187: ...nction parameter address express rules Take frequency inverter function parameter serial numbers as register address which are divided into the high byte and the low byte two parts The high byte expre...

Страница 188: ...hout storing if the parameter function code address high four digit is 1 wirte in EEPROM namely power off with storing For instance rewriting the function parameter E 16 not depositing to EEPROM addre...

Страница 189: ...R W charact eristic Communication given frequency 3000H Communication giving frequency value power off without storage W R Communication order setting 3001H 0000H No order W 0001H Forward running 0002...

Страница 190: ...stop 2 L U 2 Supply power is too low during running 3 o U 1 Acceleration overvoltage 4 o U 2 Deceleration overvoltage 5 o U 3 Constant speed overvoltage 6 o U 4 Close down overvoltage 7 o C 1 Accelera...

Страница 191: ...5 2 7 Error meaning of slave machine responding abnormal information Error code Specification 1 Command code error 2 Communication transmission error 3 CRC checking error 4 Illegal address 5 Illegal...

Отзывы: