11
Input order
signals
Start, stop, positive and negative rotating , jog,
multi-steps speed, free parking, reset, acceleration
and deceleration time choice, frequency settings
channels choice, external malfunctions alarm
External
output signal
Relay output, the collector output, 0-10V output,
4-20mA output, the frequency pulse output
Protection function
Overvoltage,
undervoltage,
current
limiting,
over-current, overload, electric thermal relays,
overheat,
pressure stall
, data protection
Dis
pla
y
Setting
Function number、data
Running
Output frequency, give frequency, output current,
input voltage, output voltage, motor speed, PID
feedback, quantitative PID, module temperature, input
and output terminal
Fault
Overvoltage, undervoltage, overcurrent, short
circuit, phase missing, overload, heat, pressure
stall, current limiting, data protection is damaged,
current fault operating conditions, historical fault
Con
dit
ion
Installation
sites
Indoor, elevation of not more than 1000 m, no corrosive
gases and direct sunlight
Temperature,
humidity
-10—+40℃, 20%—90%RH(No condensation)
Vibration
Below 20Hz less than 0.5g
Storage
Temperature
-25—+65℃
Installation
mode
Wall-mounted mode, closet mode
Protection
degree
IP20
Cooling Mode
Forced air-cooling
2.4
Inverter rated output current
Input
current
220V
380V
660V
1140V
Rated power
Rated output
current(A)
Rated output
current(A)
Rated output
current(A)
Rated output
current(A)
0.4
2.5
Содержание AC60 series
Страница 1: ...Manual AC60 series frequency inverter Version V2 0...
Страница 30: ...26...
Страница 44: ...40 2 Double display keyboard cycle switch the display of monitoring parameter mode...
Страница 46: ...42 2 Double display keyboard parameter setting mode...
Страница 162: ...158 8 2 2 Over current...
Страница 163: ...159 8 2 3 Over voltage...
Страница 164: ...160 8 2 4 Supply voltage is too low...
Страница 165: ...161 8 2 5 Inner inverter over heat...
Страница 166: ...162 8 2 6 Over load...
Страница 167: ...163 8 2 7 No display 8 2 8 Motor heat...
Страница 168: ...164 8 2 9 Motor does not rotate...