10
Carrier
frequency
1.0-15.0KHz、Random carrier modulation
Torque
upgrade
0~25.0% adjustable、auto torque upgrade、random V/F
curve optional
Maximum
Capacity
G、H、L model:150% for one minute, 180% for 2s, 200%
instant jump.
Z model:150% for one minute, 180% for 30s ,250% instant
jump.
P model:120% for one minute, 150% instant jump.
Acceleration
and
Deceleration
time
0.1-6500s
Rated output
voltage
Take advantage of the power supply voltage
compensation function, if motor rated voltage is
100%,the voltage can be set in the 50 -100% scope(the
voltage output should not exceed the input voltage )
Automatic
voltage
adjustment
function
When the grid voltage fluctuates, changes in the
output voltage is very small, remained constant V /
F
Automatic
energy-savin
g operation
According to the load conditions, automatic optimize
the V / F curves to implement energy saving operation
Standard
functions
PID control, Acceleration and deceleration time
adjustable, Acceleration and deceleration mode
variable, Carrier frequency adjustment, Torque
upgrade, Current limiting, Speed tracking and
restart, Frequency hopping, Frequency fluctuation
limite control, Program running, Multi-steps speed,
Pendulum frequency operation, RS485, Analog output,
Pulse output frequency
Brake
Energy-consuming braking, DC braking
Frequency
setting input
Keyboard number settings, keyboard potentiometers、
external terminal VS1 : 0 ~ 10V, external terminal VS2:
- 10V - 10V, the external terminal AS : 4-20mA, RS485
and signal composition and terminal options
Signal
Feedback
input
External terminal VS1 : 0 ~ 10V, external terminals
VS2:-10V - 10V, external terminal AS : 4-20mA, RS485,
frequency pulse input
Содержание AC60 series
Страница 1: ...Manual AC60 series frequency inverter Version V2 0...
Страница 30: ...26...
Страница 44: ...40 2 Double display keyboard cycle switch the display of monitoring parameter mode...
Страница 46: ...42 2 Double display keyboard parameter setting mode...
Страница 162: ...158 8 2 2 Over current...
Страница 163: ...159 8 2 3 Over voltage...
Страница 164: ...160 8 2 4 Supply voltage is too low...
Страница 165: ...161 8 2 5 Inner inverter over heat...
Страница 166: ...162 8 2 6 Over load...
Страница 167: ...163 8 2 7 No display 8 2 8 Motor heat...
Страница 168: ...164 8 2 9 Motor does not rotate...