131
H-01
Free-setting
voltage V1
Range:0.0%~[H-03]
Factory setting:
0.0%
H-02
Free-setting
frequency F1
Range:0.00Hz~[H-04]
Factory setting:
0.00Hz
H-03
Free-setting
voltage V2
Range:[H-01~H-05]
Factory setting:
25.0%
H-04
Free -setting
frequency F2
Range:[H-02~H-06]
Factory setting:
12.50Hz
H-05
Free-setting
voltage V3
Range:[H-03~H-07]
Factory setting:
50.0%
H-06
Free-setting
frequency F3
Range:[H-04~H-08]
Factory setting:
25.00Hz
H-07
Free-setting
voltage V4
Range:[H-05~H-09]
Factory setting:
75.0%
H-08
Free-setting
frequency F4
Range:[H-06~H-10]
Factory setting:
37.50Hz
H-09
Free-setting
voltage V5
Range:[H-07]~100.0%
Factory setting:
100.0%
H-10
Free-setting
frequency F5
Range :[ H-08 ] ~ maximum
frequency
Factory setting:
50.00Hz
Free-setting V/F curve:
Users set the 1st / 2nd / 3rd/ 4th / 5th voltage percentage of V / F curves,
base on frequency inverter rated output voltage 100%,corresponding to the
F1/F2/F3/F4/F5 frequency points. Users set the 1st / 2nd / 3rd/ 4th / 5th
frequency values of V / F curves, corresponding to the V1/V2/V3/V4/V5.
Содержание AC60 series
Страница 1: ...Manual AC60 series frequency inverter Version V2 0...
Страница 30: ...26...
Страница 44: ...40 2 Double display keyboard cycle switch the display of monitoring parameter mode...
Страница 46: ...42 2 Double display keyboard parameter setting mode...
Страница 162: ...158 8 2 2 Over current...
Страница 163: ...159 8 2 3 Over voltage...
Страница 164: ...160 8 2 4 Supply voltage is too low...
Страница 165: ...161 8 2 5 Inner inverter over heat...
Страница 166: ...162 8 2 6 Over load...
Страница 167: ...163 8 2 7 No display 8 2 8 Motor heat...
Страница 168: ...164 8 2 9 Motor does not rotate...