151
system continues working according to the state confirmed in the lastest
communication.
H-73 Response delay
Range:0.000~1.000 second
Factory setting:
0.005second
This parameter defines the intermediate interval time between the
frequency inverter receiving the data and responding data back to the
superordinate machine. If the response delay time is shorter than the system
handling time, the response time should according to the system; If the response
delay time is longer than the system handling time, after system processing
the data, it waits until the response delay time is up, then sends data to the
superordinate machine.
H74/H75/H76/H77/H78/H79/80
Reversed