Serial Interface Manual
•
TLS2 Monitoring Systems
Part No. 577013-767, Revision H
36
Function Code:
20D
Version 1
Function Type:
In-Tank Stick Height Report
Command Format:
Display:
<SOH>I20DTT
Computer:
<SOH>i20DTT
Notes:
1.
This command will respond only if stick height is enabled.
Tank stick height is fuel height (without tilt) + stick
offset. If the stick height is less then zero, it will be
set to zero. If the stick height is greater than tank
diameter, it will be set to tank diameter.
Typical Response Message, Display Format:
<SOH>
I20D01
22-05-01 14:57
STATION HEADER 1....
STATION HEADER 2....
STATION HEADER 3....
STATION HEADER 4....
TANK STICK HEIGHT
TANK PRODUCT LABEL INCHES
1 REGULAR UNLEADED 79.24
<ETX>
Typical Response Message, Computer Format:
<SOH>i20DTTYYMMDDHHmmTTFFFFFFFF...
TTFFFFFFFF&&CCCC<ETX>
Notes:
1.
YYMMDDHHmm - Current Date and Time
2.
TT - Tank Number (Decimal, 00 = all)
3.
FFFFFFFF - Stick Height (ASCII Hex IEEE float)
4.
&& - Data Termination Flag
5.
CCCC - Message Checksum