Serial Interface Manual
•
TLS2 Monitoring Systems
Part No. 577013-767, Revision H
41
Function Code:
21F
Version 4
Function Type:
Manual Shift Inventory Snapshot Report
Command Format:
Display:
<SOH>I21Fssdd
Computer:
<SOH>i21Fssdd
Notes:
1.
ss - number 00=all, 01, 02, 03, 04 shift number (Decimal)
2.
dd - number Day of Shift
00=all days
01=current day
02=current day-1
03=current day-2
Typical Response Message, Display Format:
<SOH>
I21F01
22-05-01 14:56
STATION HEADER 1....
STATION HEADER 2....
STATION HEADER 3....
STATION HEADER 4....
SHIFT 1
TANK TIME VOLUME TC VOLUME ULLAGE HEIGHT WATER TEMP
1 08-05-15 06:00 8518 8492 1482 76.26 0.00 64.57
2 08-05-15 06:00 8518 8492 1482 76.26 0.00 64.57
3 08-05-15 06:00 8518 8492 1482 76.26 0.00 64.57
<ETX>
Typical Response Message, Computer Format:
<SOH>i21F00YYMMDDHHmmssCCttpYYMMDDhhmmNNFFFFFFFF...
ttpYYMMDDhhmmNNFFFFFFFF&&CCCC<ETX>
Notes:
1.
YYMMDDHHmm - Current Date and Time
2.
ss - Shift number (Decimal, 01-04, 00=all)
3.
CC - Number of Tanks to follow (Decimal)
4.
tt - Tank number (Decimal)
5.
p - Product Code (single ASCII character, [20h-7Eh)
6.
YYMMDDHHmm - Shift Date and Time close for each tank
7.
NN - Number of eight character Data Fields to follow (Hex)
8.
FFFFFFFF - ASCII Hex IEEE floats:
1. Volume
2. TC Volume
3. Ullage
4. Height
5. Water
6. Temperature
7. Water Volume
9.
&& - Data Termination Flag
10.
CCCC - Message Checksum