Serial Interface Manual
•
TLS2 Monitoring Systems
Part No. 577013-767, Revision H
120
Function Code:
88A
Version 1
Function Type:
Set Communications Port Type
Command Format:
Inquire:
Display:
<SOH>S88APPt
<SOH>I88APP
Computer:
<SOH>s88APPt
<SOH>i88APP
Notes:
1.
PP - Communication Port Number (Decimal 01-03) Inquiry and Set
commands work for the first 3 ports (Decimal 01-03). The
ports can be set to the following values:
Port 1: 0 = Printer, 1 = Modem, 2 = Serial, 3 = None
Port 2 & 3: 2 = Serial, 3 = None
Typical Response Message, Display Format:
<SOH>
I88A01
22-05-01 15:12
PORT COMMUNICATIONS TYPE
COMM 1: SERIAL
<ETX>
Typical Response Message, Computer Format:
<SOH>i88APPYYMMDDHHmmt&&CCCC<ETX>
Notes:
1.
YYMMDDHHmm - Current Date and Time
2.
t - Communications Port Type:
0 = Printer
1 = Modem
2 = Serial
3 = None
3.
&& - Data Termination Flag
4.
CCCC - Message Checksum