Serial Interface Manual
•
TLS2 Monitoring Systems
Part No. 577013-767, Revision H
43
Function Code:
233
Version 6
Function Type:
Density Offset History Report
Command Format:
Display:
<SOH>I233TT
Computer:
<SOH>I233TT
Typical Response Message, Display Format:
<SOH>
I23300
16-06-11 07:35
DENSITY OFFSET HISTORY REPORT
T 1:REGULAR UNLEADED
DATE / TIME DENSITY TEMP TC DENSITY TC REF TEMP TC OFFSET
16-06-11 07:35 TLS: 45.062 71.50 45.459 59.00 0.000
FIELD: 45.060 71.50 45.464 59.00 0.005
TOTAL: 0.005
<ETX>
Typical Response Message, Computer Format:
<SOH>i233TTYYMMDDHHmmTTNNYYMMDDHHmmnnFFFFFFFF...FFFFFFFF
YYMMDDHHmmnnFFFFFFFF...FFFFFFFF...
TTNNYYMMDDHHmmnnFFFFFFFF...FFFFFFFF
YYMMDDHHmmnnFFFFFFFF...FFFFFFFF&&CCCC<ETX>
Notes:
1.
YYMMDDHHmm - Current Date and Time
2.
TT - Tank Number (Decimal, 00=all)
3.
NN - Number of Records to follow (Hex)
4.
YYMMDDHHmm - Date/Time
5.
nn - Number of eight character Data Fields to follow (Hex)
6.
FFFFFFFF - ASCII Hex IEEE float:
1. TLS Density
2. TLS Temp
3. TLS TC Density
4. Previous TC Ref Temp
5. Previous Total TC Density Offset
6. Field Density
7. Field Temp
8. Field TC Density
9. TC Ref Temp
10. TC Density Offset
11. Total TC Density Offset
7.
&& - Data Termination Flag
8.
CCCC - Message Checksum