Serial Interface Manual
•
TLS2 Monitoring Systems
Part No. 577013-767, Revision H
123
Function Code:
893
Version 4
Function Type:
Acknowledge Tank Event Ready Status
Command Format:
Inquire:
Display:
<SOH>S89300149
<SOH>I89300
Computer:
<SOH>s89300149
<SOH>i89300
Notes:
1.
149 - This verification code must be sent to confirm the command
Typical Response Message, Display Format:
<SOH>
I89300
22-05-01 14:58
Tank Delivery Ready Shift Ready Alarm Notice
===================================================
1 Yes No No
2 No No No
<ETX>
Typical Response Message, Computer Format:
<SOH>i89300YYMMDDHHmmNNttnndsa...
NNttnndsa&&CCCC<ETX>
Notes:
1.
YYMMDDHHmm - Current Date and Time
2.
NN - Number of Tanks to follow (Decimal)
3.
tt - Tank Number (Decimal)
4.
nn - Number of Events to follow (Decimal)
5.
d - Delivery Ready Status (0=not ready, 1=Ready)
6.
s - Shift Ready Status (0=not ready, 1-4[shift number]=Ready)
7.
a - Alarm Notice Status (0=not ready, 1=Ready)
8.
&& - Data Termination Flag
9.
CCCC - Message Checksum