3.2.16
Main power
The main power is controlled by the ignition switch.
The main power is automatically turned on when you turn the ignition to other
than the OFF position. When you turn the ignition to the OFF position, the main
power is turned off after a delay. During this delay, data is saved, the system
performs a controlled shutdown and the urea system lines become empty. The
light in the light switch is lit until the main power is switched off.
The main power is not switched off automatically in the following situations:
•
the parking lights are on
•
the hazard warning flasher is on
•
the control electronics request for additional time, for example the Autoguide
system
3.2.17
Using the main power emergency button
If in an emergency, you can use the separate main power emergency button to
switch off all power immediately and without delay. In normal use, the main
power is switched off after a delay when you turn the ignition to the OFF position,
and there is no need to use the main power emergency button.
1
2
3
GUID-662324B9-8FB4-4FF7-BEDB-61435F936ACF
1. Main power emergency button
2. Main power on (green light)
3. Main power off (red light)
1. Turn the ignition to the OFF position and remove the key from the ignition
switch.
2. Open the cover of the electric centre.
3. Operation
- 70 -