Warning message on the instrument panel display
Action
SLOW DOWN
PTO SPEED TOO HIGH!
•
The ground speed PTO speed is above limit of
1800 rpm.
•
The buzzer alarms once.
•
When the speed of the ground speed PTO has
dropped low enough, the buzzer goes out and
the display returns to the previously selected
state.
SECONDARY BRAKE!
•
The emergency brake is in use.
•
The message is displayed as long as the
emergency brake button is pressed or
emergency brake lever is pulled.
SECONDARY BRAKE!
FAULT!
•
There is a fault in the emergency brake and it
does not function.
•
A service code is displayed on the tractor
terminal display.
•
Contact an authorised Valtra workshop.
PARKING BRAKE
FAULT!
•
There is a fault in the parking brake and it might
not function properly. This can also prevent the
function of the emergency brake.
•
The buzzer alarms continuously and a service
code is displayed on the tractor terminal display.
•
Contact an authorised Valtra workshop.
Fuel Level Sensor Has Open Circuited
•
Fuel level sensor has open-circuited.
•
Contact an authorised Valtra workshop.
Fuel Level Sensor Has Short Circuited
•
Fuel level sensor has short-circuited.
•
Contact an authorised Valtra workshop.
5.3
Identifying a blocked transmission or hydraulic system
filter
When the pressure oil filter clogging indicator light
is lit the filter of the
transmission or hydraulic system is blocked. Note that the indicator light may
blink for some time when starting the tractor before the oil warms up.
If the indicator light is lit when the oil has been warmed, the transmission
lubrication filter is probably blocked. If the indicator light is lit when using auxiliary
hydraulics, it is probably only the hydraulic return filter which is blocked.
NOTE: The lubrication filter and the low pressure filter of the transmission are
identical.
5. Troubleshooting