5. Run a sample product through the glue station.
6. Stop the parent machine before the product is folded and measure the glue pattern (Figure 41).
Note!
The glue pattern should be glue (6 inches, 152.4 mm) - flap (1 inch, 25.4 mm) = 5 inches (127 mm).
7. If the glue pattern is incorrect, ensure that the “flap” and the “glue” switches are in the correct positions. If
glue pattern is still incorrect, see
Section 7—Initial Setup
.
Note
!
The parent machine must run above the minimum speed setting in order for the glue valve to operate.
If the minimum-speed LED is off, the parent machine is running below the minimum speed. The
minimum-speed LED is located on the lower center of the main board.
8. Adjust the fluid-flow control adjust knob on the front panel (Figure 8-4) to increase or decrease the amount
of glue being applied.
Figure 8-4 Glue-Pattern Measurement
Fluid-Flow Control (EPC)
The fluid-flow control (EPC) is enclosed within the VC350A control. The operation interface is a simple adjust
knob that is adjusted from the front panel. A clockwise rotation increases the pressure and a CCW rotation decreases
the pressure.
The amount of pressure seen on the front panel gauge is the air pressure boost that is added to the preset pressure at
the glue regulator. For example, the “T” handle on the glue regulator is normally set at 10 psi. If the EPC pressure is
adjusted to 10 psi at jog speed, then the final pressure at the glue regulator will be 20 psi.
As the parent machine increases in speed, the glue pressure automatically increases. If there is too much glue on the
product at normal operating speed, the pressure-control knob may be used to decrease the glue pressure.
Note!
The glue regulator “T” handle should never be adjusted.
Likewise, as the parent machine decreases in speed, the glue pressure automatically decreases. If there is not enough
glue on the product, the front-panel knob may be used to increase the glue pressure.
Note!
The glue regulator “T” handle should never be adjusted.
(127 mm)
Содержание VC350A
Страница 1: ...VC350A Flexoseal System Manual Number MC037 Release Date May 2001 ...
Страница 8: ...Section 1 Introduction VC350A Flexoseal System Valco Cincinnati 1 2 Figure 1 1 VC350A Control ...
Страница 68: ...Section 9 Maintenance VC350A Flexoseal System Valco Cincinnati 9 9 Figure 9 4 Fluid Regulator ...
Страница 79: ...Section 10 Troubleshooting VC350A Flexoseal System Valco Cincinnati 10 9 Figure 10 2 No Glue Flowchart ...
Страница 95: ...Section 12 Part Number List VC350A Flexoseal System Valco Cincinnati 12 6 Shaft Encoder Assembly 155xx001 ...
Страница 105: ...Section 12 Part Number List VC350A Flexoseal System Valco Cincinnati 12 16 Mounting Bracket Assembly 578xx530 ...
Страница 107: ...Section 12 Part Number List VC350A Flexoseal System Valco Cincinnati 12 18 Scanner Mounting Bracket Assembly 581xx157 ...
Страница 113: ...Section 12 Part Number List VC350A Flexoseal System Valco Cincinnati 12 24 Glue Station Top Down Tab Side 578xx644 ...
Страница 115: ...Section 12 Part Number List VC350A Flexoseal System Valco Cincinnati 12 26 Glue Station Bottom Up Tab Side 578xx649 ...
Страница 117: ...Section 12 Part Number List VC350A Flexoseal System Valco Cincinnati 12 28 Conversion Kit Assembly 723xx003 ...
Страница 119: ...Section 12 Part Number List VC350A Flexoseal System Valco Cincinnati 12 30 3 Way valve 12VDC 411xx751 ...
Страница 127: ...Section 12 Part Number List VC350A Flexoseal System Valco Cincinnati 12 38 LP366WGT Low Pressure Glue Valve 705xx112 ...
Страница 129: ...Section 12 Part Number List VC350A Flexoseal System Valco Cincinnati 12 40 0 40 mm 0 016 Zoll 08 Glue Valve 703xx907 ...
Страница 131: ...Section 12 Part Number List VC350A Flexoseal System Valco Cincinnati 12 42 366 Glue Valve Assembly 706xx051 ...
Страница 133: ...Section 12 Part Number List VC350A Flexoseal System Valco Cincinnati 12 44 400EZ Glue Valve ...
Страница 135: ...Section 12 Part Number List VC350A Flexoseal System Valco Cincinnati 12 46 Scanner Assembly 280xx201 3 4 1 5 6 ...
Страница 139: ...Section 12 Part Number List VC350A Flexoseal System Valco Cincinnati 12 50 Glue Filter 529 Small 593xx024 ...
Страница 143: ...Section 12 Part Number List VC350A Flexoseal System Valco Cincinnati 12 54 DD 1 Pump 66 47 5 5 11 ...
Страница 147: ...Section 12 Part Number List VC350A Flexoseal System Valco Cincinnati 12 58 Glue Regulator Option ...
Страница 159: ...Section 12 Part Number List VC350A Flexoseal System Valco Cincinnati 12 70 Air Filter Regulator Assembly 594xx031 ...
Страница 161: ...Section 12 Part Number List VC350A Flexoseal System Valco Cincinnati 12 72 Electrical Connectors ...
Страница 163: ...Section 12 Part Number List VC350A Flexoseal System Valco Cincinnati 12 74 Fittings ...
Страница 182: ...Appendix A Wiring Diagrams VC350A Flexoseal System Valco Cincinnati A 3 Figure A 2 Interface Board Schematic ...
Страница 211: ...VC350AG VC350AG VC350AG VC350AG VC350AG AutoGlue Control Operations Manual Manual Number MC060 Release Date August 2005 ...