6.SETTING AND ADJUSTMENT OF READING
76
6-6-7. Disp data selection
Use this menu item to select data to be displayed in the main/sub-arithmetic field of
comparison and message screen.
The selection item is displayed in the main/sub.
The item that can be displayed in the main-arithmetic field is Total or Feed rate.
The item that can be displayed in the sub-arithmetic field is Total or Feed rate or Target.
Operation
6-7. Control Parameter
6-7-1. Target set
・
Cont.feed rate
、
Cont.total mode
Specify target flow in t/h or kg/h (the unit depends on the [FEED UNIT] setting)
・
Fixed mode
Specify control rate to output in %.
・
Auto coordinate mode
Auto adjustment is performed using AT COORDINATE OUT 1 – 4 (Target Set value is
ignored)
・
The instrument functions as a slave
Specify the target value as a percentage to the master’s flow/target. If you select 100%,
the instrument try to control aiming at the same value as the master.
Operation
Options: TOTAL/FEED FEED/TOTAL TOTAL/TARGET FEED/TARGET
MODE
DISPLAY
DISP DATA SELECTION
→
→
MODE
CTRL. PARAMETER
TARGET SET
→
→
Range: 0.0 – 99999 (5 digits, decimal place floating with flow)
0.0 – 99.99% (4 digits, decimal place fixed)