6.SETTING AND ADJUSTMENT OF READING
60
6-3-8. SI/FII ID
Use this menu item to set an ID to each of the F805AT-BCs linked to SI/FII network.
Up to eight F805AT-BCs can be connected in SI/FII network, up to four of them can be
operate as masters. They are grouped together using the ID (see the figure below) to
form up to four groups.
This scheme allows F805AT-BCs with different ID number to be linked in the same
network, contributing to reduce wiring cost and simplify maintenance.
Operation
6-4. Comparison
6-4-1. Alarm upper limit
alarm lamp comes on if the item set in [ALARM MODE] exceeds this set
value (
is displayed in reversed red while RUNNING), and the external output
HI turns ON.
This value is ignored if “COMPARISON OFF” is selected in [ALARM MODE].
Operation
F805AT-BC
ID =0
ID =1
ID =2
ID =3
Master
F805AT-BC
Master
F805AT-BC
Master
F805AT-BC
Master
F805AT-BC
Slave
F805AT-BC
Slave
F805AT-BC
Slave
F805AT-BC
Slave
ID =0
ID =1
ID =2
ID =3
Range: 0 – 3 (1 digit)
MODE
COMMUNICATION
→
→
PAGE
→
SI/FII ID
PAGE
→
HI
HI
MODE
COMPARISON
→
→
ALARM UPPER LIMIT
Range: 0 – 999.99% (5 digits, decimal place fixed)
Содержание F805AT-BC
Страница 1: ...F805AT BC BELT SCALE CONTROLLER 15 Feb 2019 Rev 1 03 OPERATION MANUAL...
Страница 15: ...CONTENTS XIV M E M O...
Страница 202: ......