11.TROUBLESHOOTING
159
11-3. Calibration Error Display
11-4. Sequence Error Display
Description
Alarm message
Alarm
No.
Re-calibration required
CAL. ERR 1
1
Initial dead load subtraction exceeds the zero adjustable
range
CAL. ERR 2
2
Initial dead load subtraction produces a minus value
CAL. ERR 3
3
Span setting exceeds the CAPACITY value
CAL. ERR 4
4
“00000” is entered for span setting
CAL. ERR 5
5
Load cell (weighing device) output falls short of span-
adjustable range
CAL. ERR 6
6
Load cell (weighing device) output swings to minus range
CAL. ERR 7
7
Load cell (weighing device) output exceeds the span-
adjustable range
CAL. ERR 8
8
Error Description
Alarm message
Alarm
No.
Abnormal AT COORDINATE value.
SEQ. ERR 1
1
System halted due to “control deviation over”
SEQ. ERR 2
2
System halted due to “control deviation under”
SEQ. ERR 3
3
System halted due to “control limit over”
SEQ. ERR 4
4
System halted due to “belt speed over”
SEQ. ERR 5
5
System halted due to “weight density over”
SEQ. ERR 6
6
System halted due to “feed rate over”
SEQ. ERR 7
7
System halted due to “load ratio over”
SEQ. ERR 8
8
System halted due to “feed ratio over”
SEQ. ERR 9
9