6.SETTING AND ADJUSTMENT OF READING
92
Press
to proceed to the next screen,
or press
to return to the previous screen.
4) Input/output check
Use this item to check external I/O.
Press
to output signal to the output pins (17-24, 42-49) of the control
connector located in the rear panel. Output indicator changes from “-“ to “0”.
Press
to end the output check.
If you enter external signal to the input pins (2-9, 11-14, 27-34, 36-39), the input
indicators change from “-“ to “0”.
5) BCD output check (BCO)
6) BCD input check (BCI)
7) D/A check (DAC)
8) ANA check (ANA)
・
BCD output board check (BCO)
This function performs I/O check of BCD parallel output interface.
Press
to send signal sequentially to the output pins (2-18, 20-26) of the
rear panel BCD OUTPUT connector.
Output indicator changes from “-“ to “0”.
Press
to end the output check.
If you enter external signal to the input pins (27-34), the input indicators change from
“-“ to “0”.
PAGE
BACK
START
STOP
These items appears only
if the option board is installed
START
STOP