2.FRONT PANEL AND REAR PANEL
6
2-2. Rear Panel
1.
AC power source input connector/ DC power source input terminal block
AC spec.
Connect with AC power source cable supplied.
Input voltage is AC100V~240V (+10% -15%), and frequency is 50/60Hz.
DC spec. (Designated when it is shipped.)
Connect DC power source. Voltage input is DC12~24V (±15%).
2. Frame ground
Please ground the frame ground terminal to prevent failures due to static electricity.
It may be better to remove depending on the environment of the installation location.
3. Protective ground
(DC spec. only)
Be sure to ground the protective ground terminal to prevent electric shocks.
④
Option slot
⑩
Load cell
⑨
SI/F terminal
⑦
Control signal
⑧
SI/FII terminal
⑥
LOCK switch
⑤
RS-232C
②
Frame ground
①
AC power input
*DC spec.(Designated when it is shipped)
Red (plus)
Black (minus)
②
Frame ground
①
DC Power source
Input / Output connector
connector
connector
connector
block
block
input terminal block
③
Protective ground