10.ARITHMETICS
155
10-8. Error Measure
When you carry out error measurement using [ZERO ERROR MEASURE] screen, set
0.00% to [ZERO ERROR]. when you carry out error measurement using [SPAN
ERROR MEASURE] screen, set 0.00% to [SPAN ERROR].
10-9. Compensation
10-10. Equivalent Target ([kg/h], [t/h])
* If the instrument is operated as a slave, these values are replaced by:
Zero Error Measure
=
Standard Feed zero
[
kg
]
Total
[
kg
]
× 100
Span Error Measure
=
Standard Feed Span [kg]
× 100
Total
[
kg
]
-
Standard Feed Span [kg]
Zero compensation factor
=
×
Zero error measure
100
Capacity [kg]
Weighing section [m]
Span compensation factor
=
100
+
Span error measure
Equivalent target ([kg/h], [t/h]) (CONT. FEED RATE)
=
Target [kg/h], [t/h]
Equivalent target ([kg/h], [t/h]) (CONT. TOTAL)
=
Target ([kg/h], [t/h]) × Elapsed time [h]
-
Total [t]
Update frequency [s]
×3600
Master’s flow/target ([kg/h], [t/h])
×
slave’ target [%]
100
Содержание F805AT-BC