16.SETTING ITEMS LIST
183
Analog IN/OUT (Option)
Setting Item
Initial value
NOV.
RAM
Lock
(
hard
)
Lock
(
soft
)
PASS
WORD
Input
method
Decimal
place
AO Output Channel
ch1
Selection 3
-
AO Output
Mode
ch1
LOAD RATIO
◎
◎
Selection 7
-
ch2
BELT SPEED
◎
◎
Selection 7
-
ch3
WEIGHT DENSITY
◎
◎
Selection 7
Type
AO Zero Output
Weight
ch1
0.00
◎
◎
Numeric
Type
ch2
0.00
◎
◎
Numeric
Type
ch3
0.00
◎
◎
Numeric
Type
AO Full Scale
Value
ch1
100.00
◎
◎
Numeric
Type
ch2
100.00
◎
◎
Numeric
Type
ch3
100.00
◎
◎
Numeric
Type
AO Output
Compensation
ch1
0.0
◎
◎
Numeric
1: fixed
ch2
0.0
◎
◎
Numeric
1: fixed
ch3
0.0
◎
◎
Numeric
1: fixed
AO Lower Limit
ch1
0.00
◎
◎
Numeric
2: fixed
ch2
0.00
◎
◎
Numeric
2: fixed
ch3
0.00
◎
◎
Numeric
2: fixed
AO Upper Limit
ch1
100.00
◎
◎
Numeric
2: fixed
ch2
100.00
◎
◎
Numeric
2: fixed
ch3
100.00
◎
◎
Numeric
2: fixed
AI Input Channel
ch1
Selection 2
-
AI Zero Set
ch1
0.0
◎
◎
◎
Command
-
ch2
0.0
◎
◎
◎
Command
-
AI Full Scale Set
ch1
100.0
◎
◎
◎
Command
-
ch2
100.0
◎
◎
◎
Command
-
AI Digital Filter
ch1
64 Times
◎
◎
◎
Selection 7
-
ch2
64 Times
◎
◎
◎
Selection 7
-
Target Entry Select
NONE
◎
◎
Selection 3
-
AI Target Value
100.00
◎
◎
Numeric
Flow
AI Min. Scale Div.
0.1
◎
◎
Numeric
1: fixed
Speed Entry Select *3
ANALOG CH1
MODE
◎
◎
◎
Selection 5
-
*3 If DAC is installed in the system, SPEED ENTRY SELECT is defined in the corresponding field in DAC
menu: this item does not appear in this menu.
MODE
PAGE
OPTION
Содержание F805AT-BC
Страница 1: ...F805AT BC BELT SCALE CONTROLLER 15 Feb 2019 Rev 1 03 OPERATION MANUAL...