11.TROUBLESHOOTING
160
11-5. ANA Error Display
* ANA errors are displayed only for the system with an installed analog IN/OUT
interface: these messages may appear in the execution screen when [AI ZERO SET]
or [AI FULL SCALE SET] setting is performed.
11-6. Priority for Error Display
When plural of errors occur simultaneously, they are reported in the priority order
shown below:
TOTAL FINAL OVER is displayed above the calculated value only when TOTAL is
selected in [DISP DATA SELECTION].
Error Description
Alarm message
AI zero setting is done when the input is below the minimum value
ANA ERR 1
AI zero setting is done when the input is over the maximum value
ANA ERR 2
AI full-scale setting is done when the input is below the minimum value
ANA ERR 3
AI full-scale setting is done when the input is over the maximum value
ANA ERR 4
AI full-scale setting was done for too small input
ANA ERR 6
AI full-scale setting was done for minus input
ANA ERR 7
Priority
Error/Over scale
High
Low
CAL. ERR
EXC. ERR
LOAD, -LOAD
SEQ. ERR
OFL1
OFL2
OFL3
OFL4
OFL5
FEED ERROR
DEV.LIM OVER
DEVIATION OVER
DEVIATION UNDER
DEV.EXC. OVER
EXC UNDER
MASTER ERROR
TOTAL OVER