9.OPTION (Option card required)
137
9-2-4. Level input mode (STROBE short-circuited)
9-2-5. Edge input mode
・
Data/code input: Close: 1, Open:0
・
STROBE is an edge trigger signal: data/code is read in at the rising edges (e.g.
Transition from Close to Open).
・
ACK pulse is returned if the data is successfully read.
・
NACK pulse is returned if any abnormal Hex code (A to F) is detected: the set value
is not updated.
9-2-6. Data code (23, 24, 25 pin)
0.5 sec
0.5 sec
read set value
read set value
Data
Code
STROBE
t1
t2
t3
t4
ON
ON
Data
Code
STROBE
Pulse output in
NAK
2-18
23-25 pins
26 pin
27 pin
28 pin
t1
≧
0mSec
t2
≧
120mSec
t3
≧
25mSec
t4
≧約
120mSec
20-22 pins
ACK
or
4
2
1
Setting Value
Open
Open
Open
Upper limit
Open
Open
Close
Lower limit
Open
Close
Open
Rated belt speed
Open
Close
Close
Moisture ratio
Open
Open
Open
Target value
Open
Open
Close
Start coordin. value
Open
Close
Open
Not used
Open
Close
Close
Not used