59
Used for:
Direct Mode & Form Edit Mode
Syntax:
Aa,b,c,d,e,f,g,"DATA"
where...
a
=
Horizontal start position (x) in dots
b
=
Vertical start position (y) in dots
1
The start position for a field is determined by the upper left
corner of the field.
c
=
0
No Rotation
1
90 degrees rotation clockwise
2
180 degrees rotation clockwise
3
270 degrees rotation clockwise
d
=
Font selection
2
:
1
20.3 cpi, 6 points, (8 x 12 dots)
2
16.9 cpi, 7 points, (10 x 16 dots)
3
14.5 cpi, 10 points, (12 x 20 dots)
4
12.7 cpi, 12 points, (14 x 24 dots)
5
5.6 cpi, 24 points, (32 x 48 dots)
e
=
Horizontal multiplier 1, 2, 3, 4, 6, 8.
Magnifies the text horizontally.
f
=
Vertical multiplier 1, 2, 3, 4, 5, 6, 7, 8, 9.
Magnifies the text vertically.
g
=
N for Normal image
R for Reverse image
DATA =
Fixed data entry. (Must be enclosed in quotation marks).
"DATA" can be replaced by or combined with below commands:
Variable:
Vnn
nn= 2 digit number from 00 to 29. Places variable Vnn
entry in this position in this field.
Consecutive Number Counter:
Cn
n = One digit number from 0 to 9. Places counter Cn entry
in this position in this field.
or...
Cn
±
b
n = One digit number from 0 to 9. Places counter Cn entry
in this position in this field.
b = One digit number from 0 to 9. Steps up the counter's
start value with the value b.
Enter + to increment or - to decrement.
UBI EasyCoder 71 – Programming
TEXT & BAR CODE COMMANDS
A
Place Text
Continued!
1
/. When using reverse image, space
must be provided for the black back-
ground. Thus, vertical start position
≥
2
dots must be used.
2
/. Fonts 1 - 5 are non proportional. For
character availability see Appendix 3,
Fonts, Code Pages and Character Sets.