Turner OCTO
®
Assembly Guide
©Turner Access Ltd 65 Craigton Road, Glasgow, G51 3EQ, Scotland
Section 1 Page 58
TA3/01/50/01_Iss1Rev3
Rev.No.Jan17/Rev3
The following examples of Unclad Tied Wall Scaffolds are SYSTEM CONFIGURATIONS in
accordance with BS EN 12810-1:2003 (7.2 The standard set of system configurations).
They note the maximum computed leg load for the configurations built to their maximum
height to top platform level. Where this computed height is higher than 24m it is noted that
the Max. Height to Platform is 24.0m.
LIVE LOAD
The loading configurations are in accordance with BS EN 12811-1:2003(6.1.3 Load
Classes).
See Turner Fabrication interpretation of Load Class Table below.
LOAD CLASS DUTY
UDL ON
PLATFORM
kN/m
2
MAX. NUMBER OF PLATFORMS IN
USE (UDL KN/M
2
)
1
Inspection &
Very Light Duty
0.75
1 @ 100% (0.75) & 1 @ 50% (0.375)
2
Light Duty
1.50
1 @ 100% (1.50) & 1 @ 50% (0.75)
3
General
Purpose
2.00
1 @ 100% (2.00) & 1 @ 50% (1.00)
4
Heavy Duty
3.00
1 @ 100% (3.00) & 1 @ 50% (1.50)
The cantilevers are rated at the same capacity as the main platforms in all cases.
Scaffolds other than those noted in the SYSTEM CONFIGURATION must be designed
SECTION 1.7 Maximum Heights