![TruVision NVR 22 Series Скачать руководство пользователя страница 115](http://html1.mh-extra.com/html/truvision/nvr-22-series/nvr-22-series_user-manual_1177455115.webp)
Chapter 13: Alarm and event setup
TruVision NVR 22 (SP) User Manual
111
Alarm host IP represents the IP of the remote PC where the Network Video
Surveillance software installed. The alarm host port value must be the same as
software’s alarm monitor port. Up to three alarm hosts can be set. For each alarm
host, the default port is 5001, 5002, and 5003.
3. Click
Apply
to save the settings.
4. Click
Exit
to return to live view.
Intrusion integration alarm reporting
The recorder includes an alarm receiver software module for intrusion integration. This
permits SIA and XSIA events to be reported to the recorder from Aritech intrusion
panels via IP and to be linked to recorder actions.
The following Aritech panels are supported:
ATS Master (EMEA only)
Advisor Advanced
NetworX panels
Up to three intrusion panels can be set up in the recorder. Each panel can report up to
32 intrusion zones (a zone is an intrusion panel input).
The panels must support the SIA or XSIA reporting protocol. They can report the
following alarm types to the recorder:
An arming event
A disarming event
An alarm event that has an “A” as a second character in the SIA/XSIA code as well
as codes BV and HV.
Intrusion Alarm_BA (Burglary alarm)
Intrusion Alarm_TA (Tamper alarm)
Intrusion Alarm_EA (Exit alarm)
Intrusion Alarm_UA (Technical alarm
(General))
Intrusion Alarm_FA (Fire alarm)
Intrusion Alarm_WA (Technical alarm (Water))
Intrusion Alarm_GA (Technical alarm (gas))
Intrusion Alarm_ZA (Technical alarm (Low
temperature))
Intrusion Alarm_HA (Hold-up alarm)
Panel Heartbeat Alarm
Intrusion Alarm_JA (User code tamper)
Arming Panel Alarm
Содержание NVR 22 Series
Страница 1: ...TruVision NVR 22 SP User Manual P N 1073192 EN REV P ISS 15JUN22...
Страница 4: ......