9.5
Laser Configuration
Laser Configuration is used for laser diagnostics and/or laser tuning only (Chapter 10.1).
It replicates the controls available on the front panel of the laser power supply. All values are
factory set for optimum laser performance.
Warning !!!
Do not change any settings unless instructed by authorized
factory representative.
Fig.9.11. Laser Configuration.
Fig. 4.22 shows LASER SETTING panel accessible from the HMI main screen.
•
Configurable Parameters
o
Epulse (Hz) d
efines the laser pulse energy during the marking process. The
appropriate pulse energy for each type of tablets is established during initial
qualifications and set as
Nominal Pulse Energy
.
o
Frequency(Hz)
defines the laser repetition rate and the output power
o
Duration
is measured
in tenth of a second and defines the duration of the energy
test. Energy test should be done periodically during production to assure the
proper marking.