29
3.6.
AC Filter
3.6.1.
AC Reactor
The following tables show the AC reactors provided for the PWM sine wave mode.
For the AC reactors provided for the 120-degree conduction mode, contact us.
400V class
Converter model
AC reactor model
VF66R-7544
ACL7544
VF66R-11044
ACL11044
VF66R-16044
ACL16044
VF66R-20044
ACL20044
VF66R-25044
ACL25044
VF66R-31544
ACL31544
VF66R-40044
ACL20044 x 2
VF66R-50044
ACL25044 x 2
VF66R-60044
ACL20044 x 3
VF66R-75044
ACL25044 x 3
VF66R-100044
ACL25044 x 4
●
Exterior and dimensions (reference)
Model
W
H
D
Weigh
t
Model
W
H
D
Weight
ACL7522
300
320
295
58
ACL7544
300
310
290
63
ACL9022
300
320
295
65
ACL11044
360
380
320
96
ACL16044
420
400
340
125
ACL20044
420
460
340
150
ACL25044
450
520
370
190
ACL31544
480
550
400
240
(Note) Units of dimension and weight are mm and kg, respectively.
200 V class
Converter model
AC reactor model
VF66R-7522
ACL7522
VF66R-9022
ACL9022
VF66R-15022
ACL7522 x 2
VF66R-18022
ACL9022 x 2