105
8. Press the [SET] key.
・
The selection of "L-07" is confirmed, and the current setting
value (Initialized data is "0") is displayed.
・
The display of the setting value automatically returns to that
of the setting item in ten seconds. Unless a setting value is
specified while it is displayed, it cannot be changed.
9. Press the keys [
↑
] or [
↓
] to change the number to "0"
(0 to 10 V).
10. Press the [SET] key.
・
The change is confirmed, and "L-07" is displayed again.
・
The display of the setting value automatically returns to that
of the setting item in ten seconds. Unless the [SET] key is
pressed while a setting value is displayed, the change cannot
be confirmed.
11. Press the [
→
], [
↑
] or [
↓
] keys to specify "L-01."
・
For details of the analog output (2) characteristics selection:
L-01, refer to {5.3.10. Area L}.
12. Press the [SET] key.
・
The selection of "L-01" is confirmed, and the current setting
value (Initialized data is "0") is displayed.
13. Press the keys [
↑
] or [
↓
] to change the number to "0"
(AC voltage).
14. Press the [SET] key.
・
The change is confirmed, and "L-01" is displayed again.
15. Press the [
→
], [
↑
] or [
↓
] keys to specify "S-06."
・
For details of the analog output (2) adjustment: S-06, refer
to {5.3.14. Area S}.