- 34 -
tousek
/ E_TPS-20_03 / 30. 08. 2016
8. Optional Traffic light control unit STA 11
Traffic light control unit STA 11
Traffic light control board STA 11
B
88 89
Bus Low
Bus High
Operator control board TPS 20
General
• To implement traffic light function the control unit STA 11 has to be connected with the operator control unit TPS 20 via bus
system.
B
88 89
• Connection possibility of two impulse switches or induc
-
tion loops for Green request and two Red/Green traffic
lights 230V, 60W (inside and outside).
• Connection slots for optional radio receiver and induction
loop detector
•
Traffic light control board STA 11
Traffic light control STA in housing
IP 54 (210 x 310 x 125mm)
Technical data
Traffic light control board STA 11 in plastic housing IP 54 (210 x 310 x 125mm)
Power supply
230Va.c., +6/-10%, 50Hz
Relay load Red/Green traffic light
230V, max. 60W
Article no.
12120370
Optional equipment
induction loop detector ISD 6 (2-channels) • pluggable receiver