tousek
/ E_TPS-20_03 / 30. 08. 2016
- 13 -
Warning notes
•
Before taking off the control cover, the
main switch must be turned off!
•
If the control is power supplied, its inner part is under
tension.
•
In order to avoid electrical strokes, the safety regula-
tions have to be kept.
•
The device may only be connected by trained profes-
sionals.
•
The product is not suitable for installation in explosion-
hazardous areas.
•
An all-pole disconnecting main switch with a contact
opening gap of min. 3 mm has to be foreseen. The
gate facility has to be secured according to the valid
safety regulations!
•
IMPORTANT: The control lines (buttons, radio, pho
-
tocells, etc.) have to be laid separately from the 230V
lines (supply line, motors, signal lamp).
p r e - w i r e d
3.1 Terminal assignment TPS 20, TPS 20N
Sliding gate operator TPS 20, -20N
• During connection, adjustment and maintenance works please take care, that the electronic circuit
board won´t be damaged by moisture (rain).
Grounding
Power supply
230V a.c.
Signal lamp 230V
,
max. 40W
0 1
2
10 11
30 31 32 30 33 30 34
to
tr
af
fic
lig
ht
co
nt
ro
l
(optional)
power supply
ph
ot
oc
ell
tr
an
smi
tte
r
po
we
r s
up
ply
p
ho
to
ce
ll r
ec
eiv
er
and accessories, max. 0,3A
co
mmo
n
Ph
ot
oc
ell
co
nt
ac
t
ph
ot
oc
ell
co
nt
ac
t
ph
ot
oc
ell
co
nt
ac
t (
ba
ck
a
re
a)
bus system
control unit
traffic light
Low
High
88 89
transmitter
re
ce
ive
r
88 89 41 42 43 44 45 46 48
Notentriegelung
Common
Main safety sensing edge
Common
Side safety s. edge 1 OPEN
Common
Side safety s. edge 2 CLOSE
Common
Side safety s. edge 3 OPEN
bro
wn
blue
or
gray
bla
ck
green/yellow
28 29
20 21 22
23 8 9
Br
ak
e
23
0V
a
.c.
Motor 230V a.c.
Grounding
additional condenser
common
ST
OP
swi
tch
IM
PU
LS
E
swi
tch
common
CL
OS
E
swi
tch
common
pe
de
str
ian
swi
tch
Function main safety sensing edge
(MCE):
Safety during closing
Function side safety sensing edges
(SE):
Safety during opening: SE1, SE3
Safety during closing: SE2
MCE
SE2
SE3
SE1
CLOSE OPEN
8,
2k
Oh
m
8,
2k
Oh
m
8,
2k
Oh
m
8,
2k
Oh
m
58 59
50 51 50 52 50 55 50 56
If no stop switch is connected, ter-
minals 30/31 have to be wire-bridged
(the jumper is set in the factory).