tousek
/ E_TPS-20_03 / 30. 08. 2016
- 23 -
Important
•
During programming of motor the contact safety edges should not be triggered as this leads to an error
message - the limit stops have to be placed correspondingly.
G
Main closing edge
(terminals 50/51)
Safety edges
active:
to be selected if the contact strip (8,2kOhm) of main closing edge should be evaluated.
Radio edge:
to be selected if the contact strip (8,2kOhm) of main closing edge should be evaluated
with the radio
transmission system TX 310
.
TX 400:
to be selected if if the contact strip (8,2kOhm) of main closing edge should be evaluated
with the system
TX 400i
.
not active:
to be selected if the contact strip (8,2kOhm) of main closing edge should NOT be evaluated
G
Side edge 1 OPEN
(terminals 50/52)
Safety edges
active:
to be selected if the contact strip (8,2kOhm) of side edge 1 OPEN should be evaluated.
not active:
to be selected if the contact strip (8,2kOhm) of side edge 1 OPEN should NOT be evaluated.
Side edge 2 CLOSE
(terminals 50/55)
Safety edges
active:
to be selected if the contact strip (8,2kOhm) of side edge 2 CLOSE should be evaluated.
not active:
to be selected if the contact strip (8,2kOhm) of side edge 2 CLOSE should NOT be evaluated.
Side edge 3 OPEN
(terminals 50/56)
Safety edges
active:
to be selected if the contact strip (8,2kOhm) of side edge 3 OPEN should be evaluated.
Radio edge:
to be selected if the contact strip (8,2kOhm) of side edge 3 OPEN should be evaluated
with the radio
transmission system TX 310
.
TX 400:
to be selected if the contact strip (8,2kOhm) of side edge 3 OPEN should be evaluated
with the system
TX 400i
not active:
to be selected if the contact strip (8,2kOhm) of side edge 3 OPEN should NOT be evaluated
SE-status display
Safety edges
Status dsplay of safety sensing edges
MCE
main closing edge
SE2
side edge 2 CLOSE
SE1
side edge 1 OPEN
SE3
side edge 3 OPEN
Radio transmission system TX 310
•
Connection and detailed information of radio transmission system TX 310 see according manual..
Inductive system TX 400i
•
Connection and detailed information of inductive system TX 400i see according manual..
status: okay
status: not okay or triggered
status: safety sensing edge interrupted
status: not activated
$