tousek
/ E_TPS-20_03 / 30. 08. 2016
- 17 -
Main layer
Sub layer
Settings/adjustments
buttons/switches
see page 18
impulse button
OPEN/STOP/CLOSE
OPEN/CLOSE/OPEN
OPEN
DEAD MAN
*) if impulse button is set to
DEADMAN, then the pedestrian
and close button are also set
automatically to DEADMAN
mode.
(not selectable under „pedest.-
button“)
pedestrian func.
partial opening
impulse OPEN
pedestrian button
OPEN/STOP/CLOSE
OPEN/CLOSE/OPEN
OPEN
DEAD MAN
*)
emergency mode
not active
active
safety
see page 20
G
p
hotocell
active
not active
PHC- back area
not active
active
PHC-function
when closing reverse
stop - after release open
during closing stop, then close
PHC- pause time
no influence of photocell
abort pause time
re-start of pause time
immediate close after opening
PHC- self test
active
not active
safety edges
see page 22
G
Main clos. edge
active
radio edge
TX 400
not active
G
Side edge 1 OPEN
active
not active
Side edge 2 CLOSE
active
not active
Side edge 3 OPEN
active
radio edge
TX 400
not active
SE-status display
status display of safety sensing edges
motor
see page 24
max. force
25...100%
[ increment 5 ]
= 70%
incr.start.force
OFF, 0,5...3,0
[ increment 0,5 ]
= 2,0
ARS-response time
0,15...0,95s
[ increment 0,05 ]
= 0,50s
speed
40...100%
[ increment 5 ]
= 100%
soft way
0...2m
[ increment 0,1 ]
= 0,5m
soft speed
30...60%
[ increment 5 ]
= 50%
end position OPEN
0...-30
[ increment 1 ]
= -5
end position CLOSE
0...-30
[ increment 1 ]
= -5
operating mode
see page 24
impulse mode
Stop, start of pause time
impulse suppression when opening
pause time extension
G
opening direction
<<<– left
–>>> right
G
operating mode
impulse mode
automatic 1...255s [
increment
5 ]
partial opening
10...100%
[ increment 1 ]
= 30%
automatic mode
complete/partial opening
only complete opening
only partial opening
pause time logic
no influence
always open in automatic mode
additional module
courtyard lamp/control lamp
status display 1
status display 2
traffic light
not active
active
only if is
active
the corresponding
menu functions are diplayed.
lights/lamps
see page 27
prewarning OPEN
OFF, 1...30s
= OFF
prewarning CLOSE
OFF, 1...30s
= OFF
green phase
5...120s
[ increment 1 ]
= 20s
leave time
1...60s
[ increment 1 ]
= 5s
traffic gate CLOSE
red light OFF
permanent red
traffic light logic
both sides green
one side green
courtyard lamp
1)
OFF, illum. time 5...950s
= OFF
control lamp
1)
illuminates when opening/closing
blinks slowly / illuminates / blinks
illuminates in open position
diagnosis
see page 28
status display
status display of all inputs
delete positions
NO
YES
factory setting
NO
YES
software version
show software version
serial number
show serial number
protocol
show protocol notes
status sensor
show sensor
1)
The menu points courtyard lamp and control lamp will only appear on display if in menu
„Additional module“
courtyard lamp/control lamp is selected.
Menu structure
Adjustments - overview
+
–
integrated control board for sliders TPS 20, -20N, -20PRO
ESC
ENTER
No
te
: s
om
e a
dju
stm
en
ts
re
ga
rd
in
g fu
nc
tio
n o
r o
pe
ra
tin
g lo
gic
c
an
o
nly
b
e e
xe
cu
te
d if g
ate
is
c
lo
se
d a
nd
if th
e d
is
pla
y s
ho
w
s „
re
ad
y“
.
- menu function appears if „traffic light“ is
active
.
- menu function appears if „traffic light“ is
not
active
.
- the others appear constantly.