- 22 -
tousek
/ E_TPS-20_03 / 30. 08. 2016
Safety edges
Connections and adjustments
Safety sensing edges (main and side edges)
•
OBSTACLE DETECTION:
When a contact strip is triggered/activated then a change of direction is effected for 1 second. After that the gate con-
tinues to move in the changed direction.
If more safety sensitive edges are required, as shown in the figure above, (e.g. second guide column), these
have to be connected in series to the respective terminals SE1 and SE2.
Example: W
8,2kΩ final resistance
1
final edge
2+3 passage edge
S
to control board
When connecting one safety edge a final edge (1) has to be used.
1
W
2
3
S
Mai
n
safety
sen
si
n
g
ed
g
e
Side safety
sensing
edges
50
56
SE3
50
52
SE1
50
51
MCE
50
55
SE2
name in menu
short name /
status display
active in direction
terminals
choice
Main clos. edge
MCE
CLOSE
50/51
active
not active
radio edge TX
TX 400
Side edge 1 OPEN
SE1
OPEN
50/52
active
not active
Side edge 2 CLOSE
SE2
CLOSE
50/55
active
not active
Side edge 3 OPEN
SE3
OPEN
50/56
active
not active
radio edge TX
TX 400
MCE
SE2
SE3
SE1
CLOSE OPEN
Side safety sensing edges:
Safety during opening: SE1, SE3
Safety during closing: SE2
Main safety sensing edge MCE:
Safety during closing