- 14 -
tousek
/ E_TPS-20_03 / 30. 08. 2016
Elements of control box
(ST)
Control board
(see p. 12)
(FE)
Socket for radio receiver
(see p. 29)
(ISD)
Socket for induction loop detector
(see p. 29)
(REL)
Decoupling relay
(H)
Main switch
(SD)
230V Schuko socket
(X1)
Terminal block
3.2 Control box TPS 20 PRO
Sliding gate operator TPS 20 PRO
Overview of the control box
ISD
FE
REL
ST
SD
X1
H
Unlike the operators TPS 20, -20N the TPS 20
PRO has an additional terminal block X1. All
connections have to be done at this block,
which is internally connected with the control
board ST.
Warning notes
•
Before opening the control box, the
main switch must be turned off!
•
If the control is power supplied, its inner part is under
tension.
•
In order to avoid electrical strokes, the safety regula-
tions have to be kept.
•
The device may only be connected by trained profes-
sionals.
•
The product is not suitable for installation in explosion-
hazardous areas.
•
An all-pole disconnecting main switch with a contact
opening gap of min. 3 mm has to be foreseen. The
gate facility has to be secured according to the valid
safety regulations!
•
IMPORTANT: The control lines (buttons, radio, pho
-
tocells, etc.) have to be laid separately from the 230V
lines (supply line, motors, signal lamp).