Partial opening
30% (factory setting)
Operating mode
10–100% adjustable [increment 1]:
value defines the partial opening based on the total opening.
This adjustment is ONLY adopted in CLOSED-position.
Automatic mode
Operating mode
complete/partial opening:
either with complete as well as partial opening, the gate closes automatically after the
adjusted pause time.
only complete opening:
only after complete opening, the gate closes automatically after the adjusted pause time.
only partial opening:
only after partial opening the gate closes automatically after the the adjusted pause time.
Pause time logic
Operating mode
no influence
allways open in automatic mode:
if this function is activated, the control unit goes from automatic mode into impulse
mode
with activated pause time through impulse in open gate position
for this cycle , hence if gate is open then an
impulse will end the automatic mode - the gate remains open. Only the next impulse will close the gate and the control unit
goes back to automatic mode. With this function e.g. the entrance to a company site can remain open during the day (1st
impulse in gate open position) and closed in the evening (2nd impulse). The control board switches back to automatic mode
(autom. opening and closing of gate).
Additional module
Operating mode
courtyard lamp/control lamp:
the menu points courtyard lamp and control lamp are ready for adjustmenticht and Control
lamp zur Einstellung bereit (that means if not selected, these menu points will not be shown on the display)
status display 1:
with the two potential-free signal
contacts K1 and K2, the gate end positions (limits) can be
evaluated.
status display 2:
with the two potential-free signal
contacts K1 and K2, the gate end positions (limits), the
gate movement as well as a gate stop outside of the end
positions can be evaluated.
Only if an additional module
(see page 26)
is installed you can carry out one of these adjustments
(courtyard-/control l hence gate status 1 or 2).
Traffic light
Operating mode
not active
active:
Traffic light function active
• With the optional traffic light control unit, that has to be connected to the bus terminals
(B): term: 88, 89
(see picture at page 34), you can implement a traffic light operation mode.
•
Note: The functions and settings relevant for the traffic light operation are displayed in the menu only
after selecting “active” →
see
• Connection of the traffic light
-> see instruction manual of the traffic light control unit
Function
K1
K2
Gate status display
1
Gate in CLOSE-Position
1
0
Gate in OPEN-Position
0
1
2
Gate in CLOSE-Position
0
0
Gate opens or closes
0
1
Gate stopped or fault
(Gate not in end position)
1
0
Gate in OPEN-position
1
1
0 = signal contact open, 1= signal contact closed