- 26 -
tousek
/ E_TPS-20_03 / 30. 08. 2016
Additional module (optional)
Courtyard lamp/control lamp hence gate status display
• The use of one of the addtional modules is optional.
• Depending on which device, e.g. a courtyard-/Control
lamp is chosen or evaluation of gate status should be
effected, the corresponding module has to be plugged to
the according slot/plug of control board.
• Additionally the corresponding value has to be selected
in menu point „Additional module“
Connecting an additional module
• turn off power supply !
• Plug additional module
(Z)
onto the slot
(ZM)
.
Additional module Courtyard lamp/Control lamp
• On the terminals 12/13
a courtyard lamp
(H)
can be connected:
230V, max. 100W
• On the terminals 70/71
a c o n t r o l l a m p
( K )
can be connected:
24Vd.c., max. 2W
L N
12 13 70 71
H
K
– +
Additional module Gate status display
• with potential free signal
contacts K1 (term. 90/91)
and K2 (term. 92/93) the
gate staturs can be evalua-
ted in two ways (see menu
point „Additional module“).
• Contact load:
24Va.c./d.c., max. 10W
90 91 92 93
signal contact
K1
signal contact
K2
ZM
Z
ZM