-20-
5.5.3.4 Change Sign
- With key the sign can be changed for some parameters.
(Negative sign is only possible if the value is notZERO)(5.5.3.4)
5.5.3.5 Leave Parameter Level
- Press for about 3 seconds in the parameter level
- All parameters will be retentively stored in the internal flash
memory when leaving the parameter level.
(5.5.3.5)
5.5.3.6 Parameter list
5.5.3.4
5.5.3.5
Parameter:
Description:
Default:
P01: A
System configuration:
A = 0: Counting positively
A = 1: Counting negatively
1
P02: A
Display mode (affect only the display of symbols!)
A = 0: mm-Mode / Display symbol „ mm “
A = 1: Inch-Mode / Display symbol „ Inch “
A = 2: mm-Mode / Display symbol „ m “
A = 3: mm-Mode / Display symbol „ ° “
A = 4: mm-Mode / Display non symbol
0
P03: A
Decimal point ( 0 … 4 ) only for mm-Mode
1
P05: ABC
Keylock:
A: Key „Set“ (0= activated / 1= deactivated)
B: Key „Incr/Abs“ (0= activated / 1=deactivated)
C: Key „*“ (0= activated / 1= deactivated)
000
P08:
Multiplication factor ( 0,0001 … 9,9999 )
0.1000
P09:
Reference value ( -9999999 … +9999999 )
Factory setting
P10:
Offset 1 ( -9999999 … +9999999 )
0
P11:
Offset 2 ( -9999999 … +9999999 )
0
P12:
Offset 3 ( -9999999 … +9999999 )
0
P13: A
Configuration Offset (0…3)
A = 0: offset cannot be activated
A = 1: offset 1 can be activated
A = 2: offset 1 & 2 can be activated
A = 3: offset 1 & 2 & 3 can be activated
3
P90:
(without function)
0
P99:
Indicator in the company version
x.xx