-18-
5.4.4 MENU INSTRUCTION
5.4.5 FAST ADJUSTMENT
5.4.6 DIMENSIONS
5.4.7 CAUTIONS
No.
Function Description Parameter
Default parameter Parameter Description
Remarks
P00
Resolution
0.1
、
0.5
0.1
Angle display resolution
Default setting 0.1°
P01
Correction
parameters
0.0001
~
2.0000
1.0000
Angle correction parameters
Angle liner proportion
adjustment, return ERR if
adjustment fail
P02
Shake to unlock
0,
、
0.2
、
0.5
、
1
、
2 0.2
Shake exceed the
default degree, unlock
automatically.
Default setting 0.2°
P03
Lock time
0~9
5
Maintains a constant Angle
for a period of time, lock the
Angle
Default setting 5s
P04
Angle direction
0
、
1
0
Positive and negative Angle
switching
0: clockwise Angle is positive; 1:
clockwise Angle is negative
P05
Press to lock
0
、
1
0
Lock CLR
、
ZERO
、
END
0
:
unlock
;
1
:
lock
P06
Initial angle
000.0~359.9
0
Initial Angle value,
regardless of the sensor in
which position, long press
ZERO will display the Initial
Angle value
When the initial Angle shows
0, can do any position reset
function. Under the guidance
of manufacturer operation is
recommended.
P07
Final angle
000.0~359.9
45.0
Final Angle value,
regardless of the sensor in
which position, long press
ZERO will display the final
Angle value.
Default final angle is 45
°, especially designed for
woodworking machinery.
P08
Buzzer
0
、
1
1
Buzz warning every 45°
0
:
Stop to use
;
1
:
start to
use
,
-135°
、
-90°
、
-45°
、
0°
、
45°
、
90°
、
135°buzz warning
Internal calibration has been done at factory, if customers have need to do further liner calibration, please following below steps (take
woodworking equipment as an example):
1
、
Equipment operate to the initial position, long press the ZERO key, the current Angle will be set to 0 °
2
、
Equipment operate to END position, long press the END key, the current point is set to 45 °
3
、
Angle linear correction is complete. Adjust the P06, P07 data, can be set to other Angles
Sensor Dimension
Meter Dimension
Installation instructions: sensors use M3 screws, meter use back panel thimble.
-
When install this product, if the deviation is too big, will influence the use of precision, can’t even use
-
Please do not use this product in the environment of corrosion, acid or alkali, direct sunlight, etc., it may cause failure.
-
Reading head wire bending radius must be greater than 25 mm
-
The installation of this equipment should be at least 0.5 meters from the circuit breaker, relay, motor capacitor, brakes, clutch,
inverter, etc.
-
Cables direction must be separate with power lines in order to reduce noise.