-11-
A
B
3.5
Ensure that the suction system guarantees these values at the hood-houth connection point. (3.5)
Suction mouth diameter:
A - Blade guard ...... ø80 mm
B - Body dust suction ...... ø100 mm
Connect the mouths to the suction system with flexible tubes of adequate diameter. Tighten with clamps. The tube must
be positioned in such a way so as not to obstruct the operator during machining.
WARNING
Always work with the suction system on. Always start the suction system and the machine at the
same time.
3.5 DUST EXTRACTION
Proper suction eliminates the risks of dust inhalation and
aids better functioning of the machine. The tables list the
minimum air flow and speed values referenced to each
single suction operation.The related pressure drop at the
dust port is 530Pa.
WARNING
Please always use the hearing protection systems if the noise level is over 95dB(A).
The noise levels measured are emission levels and not necessarily the safe working level. Although there is a
correlation between the emission levels and the exposure levels, this cannot be used reliably to determine whether or
not further precautions are required. The factors which affect the actual level of operator exposure include the duration
of exposure, the ambient characteristics and other sources of emission, for example, the number of machines and
other adjacent machining. The permitted exposure values may also vary from country to country. Nevertheless, this
information allows the user of the machine to better evaluate the dangers and risks.
Other factors which reduce exposure to noise are:
- correct tool choice
- tool and machine maintenance
- use of hearing protection systems (e.g. headsets, earplugs,...)
3.4 NOISE LEVEL
No load Load
Sound Pressure Level < 80.4dB(A) < 85.7dB(A)
Sound Power Level < 98.1dB(A) < 100.7dB(A)
Associated uncertainty K=4dB
Measurement made in accordance with EN ISO 3746:1995 and EN ISO 11202:1995
Upper hood
Lower hood
Air flow 140 cu.m/h
690 cu.m/h
Saw
Minimum air speed 20 m/s