2-14
Installation
Use the following steps to set up the MP/16 for dial-up
management:
1
Set Console port DIP switches.
The Console port DIP
switches are located to the immediate left of the Console port.
Console
DIP Switches
Figure 2-8. Location of Console port DIP Switches
♦
Set DIP switch 3 to the DOWN (ON) position. This
configures the Console port for management.
♦
Use DIP switches 1 and 2 to set the Console port speed to
the highest speed supported by the modem. For U.S.
Robotics High Speed modems, set the port speed at 57.6K.
The following table reflects the table labeled SPEED
printed on the back of the MP/16.
Table 2-3. Console Port Speed
Switch 1
Switch 2
Speed
OFF
OFF
9600
OFF
ON
19.2K
ON
OFF
38.4K
ON
ON
57.6K