EIA RS-232 Pinouts
A-4
Connecting the MP/16 to Another DCE
It is possible to connect the MP/16 to another DCE. DCE
equipment is intended for direct connection to DTEs (dumb
terminals). To connect the MP/16 to a DCE, you can use a null
modem adapter, or rewire the cable connector to provide the
proper signaling, as in the following table.
Table B-3. Signal Assignments for MP/16 to another DCE Device
MP/16
DCE Device
Pin
Signal
Signal
1
RI
DTR
2
DCD
no connection
3
DTR
RI
4
SGND
SGND
5
RX
TX
6
TX
RX
7
CTS
RTS
8
RTS
CTS
Minimum Requirements
Some equipment supports only a few of the EIA RS-232 signal
functions—for instance, your equipment may have a 4-wire RJ11
interface. The following table lists the minimum signaling
requirements for the modems in the MP to operate.
Table B-4. Minimum Signal Requirements