Using AT Commands
C-7
Establishing a Session
Remote configuration can be performed at any time during a
connection (except synchronous connections). The user performing
remote configu ration can use any modem; it does not have to be a
U.S. Robotics model.
1
Make sure the host modem has been set for remote
configuration, as described earlier. Then establish a
connection. It does not matter which modem originates the
call.
2
After a connection has been established, the guest modem
sends the host modem the following escape sequence:
~~~~
preceeded and followed by four seconds of no transmission.
Do not press Enter
.
You can change the escape sequence character with Register
S42. The pause duration (guard time) can be modified with
Register S43. (These values are set at the host modem.)
3
The login sequence begins. The guest modem will display
something similar to the following:
U.S ROBOTICS REMOTE SESSION
SERIAL NUMBER 000000A000000001
4
At this point, if password security is active, the caller is
prompted for the password.
PASSWORD (CTRL-C TO CANCEL)?.....
If the read-only password is used, the guest can only view
settings. If the read/write password is used, the guest can also
change settings. Note that there is a 3-minute time limit for
entering the password.
If the number of unsuccessful login attempts exceeds the set
limit (Register S41), the modem returns online and refuses any
further login attempts during the remainder of that connection.
When a password is accepted, the following prompt appears
on the guest modem’s screen indicating that it has entered
remote access mode.
Содержание MP/16
Страница 4: ......
Страница 12: ...1 6 Overview...
Страница 36: ...2 24 Installation...
Страница 41: ...Using Total Control MIBs 3 5 udp The MP 16 supports the mandatory UDP User Datagram Protocol group...
Страница 150: ...D 26 AT Command Reference...
Страница 162: ...E 12 Modem Testing...
Страница 168: ...F 6 Warranty and Regulatory Information...
Страница 178: ...G 10 Technical Specifications...