Machine Behavior in Fax Reception
- 89 -
Faxing (for
e-
STUDIO403S only)
3
When using two numbers with distinct rings(DRD)
This mode is programmed for the fax to answer only on a distinctive ring. You can have a signal phone line to have
two numbers with distinct rings, one for regular phone calls and one for fax. If the phone line is in use, and there is
an incoming fax, the sender will receive a busy signal.
There are several type of DRD ring pattern. The length of ring ON time and ring OFF time is different.
It depends on the Country Code.
Please set the Country Code and DRD Type for your suitable DRD ring pattern.
z
Country Code : except New Zealand, Australia and Hong Kong (This pattern is to apply to USA's DRD.)
z
Country Code : New Zealand (This pattern is to apply to New Zealand's DRD.)
z
Country Code : Australia (This pattern is to apply to Australia's DRD.)
z
Country Code : Hong Kong (This pattern is to apply to Hong Kong's DRD.)
Setting method to change the DRD
pattern
1
Press the <
SETTING
> key.
2
Press the to select [
Admin Setup
]
and then press .
3
Enter the administrator password.
The default password is "aaaaaa".
4
Select [
Enter
] and then press .
5
Press the to select [
User Install
] and
then press .
6
Press the to select [
DRD Type
] and
then press .
7
Press the to select DRD Type and then
press .
8
Press the until the top screen appears.
DRD Type
The length of ring ON time and ring OFF time
Type1
2 sec ON - 4 sec OFF repeat
Type2
0.8 sec ON - 0.4 sec OFF - 0.8 sec ON - 4 sec OFF repeat
Type3
0.4 sec ON - 0.2 sec OFF - 0.4 sec ON - 0.2 sec OFF - 0.8 sec ON - 4 sec OFF repeat
Type4
0.3 sec ON - 0.2 sec OFF - 1 sec ON - 0.2 sec OFF - 0.3 sec ON - 4 sec OFF repeat
DRD Type
The length of ring ON time and ring OFF time
Type1
0.4 sec ON - 0.2 sec OFF - 0.4 sec ON - 2 sec OFF repeat
Type2
0.4 sec ON - 2.6 sec OFF repeat
Type3
0.4 sec ON - 0.2 sec OFF - 0.4 sec ON - 0.2 sec OFF - 0.4 sec ON - 1.4 sec OFF repeat
Type4
0.4 sec ON - 0.8 sec OFF - 0.4 sec ON - 1.4 sec OFF repeat
DRD Type
The length of ring ON time and ring OFF time
Type1
0.4 sec ON - 0.2 sec OFF - 0.4 sec ON - 2 sec OFF repeat
Type2
0.2 sec ON - 0.4 sec OFF - 0.2 sec ON - 0.4 sec OFF - 0.2 sec ON - 1.6 sec OFF repeat
DRD Type
The length of ring ON time and ring OFF time
Type1
1.2 sec ON - 3 sec OFF repeat
Type2
0.4 sec ON - 0.2 sec OFF - 0.4 sec ON - 0.2 sec OFF - 0.8 sec ON - 0.4 sec OFF repeat
Type3
0.5 sec ON - 0.5 sec OFF - 1 sec ON - 0.5 sec OFF - 0.5 sec ON - 3 sec OFF repeat
OK
OK
OK
OK
OK
Содержание e-Studio332s
Страница 1: ...MULTIFUNCTIONAL DIGITAL SYSTEMS User s Manual Basic ...
Страница 182: ...DP 3321S 4030S OME12009800 ...